Charge-sensitive amplifier front-end with an nJFET and a forward-biased reset diode

被引:9
作者
Fazzi, A
Jalas, P
Rehak, P
Holl, P
机构
[1] UNIV HELSINKI,SEFT,ESPOO 02151,FINLAND
[2] BROOKHAVEN NATL LAB,UPTON,NY 11973
[3] MAX PLANCK INST,GARCHING,GERMANY
关键词
D O I
10.1109/23.552721
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new configuration of a resistorless charge sensitive preamplifier with an nJFET as an input device was tested, The de level of the input of the amplifier was kept constant by a slightly forward-biased np junction connected between the input of the amplifier and ground, A noise level of 22 root mean square (r.m.s,) electrons is measured at 295 K and 15 r,m,s, electrons at 253 K. The dynamic behavior of the amplifier is investigated with different leakage current conditions. The technological benefits and the suitability of the front-end connection for room temperature detectors, particularly multianode drift chambers, are highlighted.
引用
收藏
页码:3218 / 3222
页数:5
相关论文
共 14 条
[1]   A NOVEL CHARGE SENSITIVE PREAMPLIFIER WITHOUT THE FEEDBACK RESISTOR [J].
BERTUCCIO, G ;
REHAK, P ;
XI, DM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :71-76
[2]   ROOM-TEMPERATURE X-RAY SPECTROSCOPY WITH A SILICON DIODE DETECTOR AND AN ULTRA-LOW NOISE PREAMPLIFIER [J].
BERTUCCIO, G ;
PULLIA, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1704-1709
[3]   HIGH-RESOLUTION X-RAY SPECTROSCOPY WITH SILICON DRIFT DETECTORS AND INTEGRATED ELECTRONICS [J].
BERTUCCIO, G ;
SAMPIETRO, M ;
FAZZI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :538-542
[5]   SUBOPTIMAL FILTERING OF 1/F-NOISE IN DETECTOR CHARGE MEASUREMENTS [J].
GATTI, E ;
MANFREDI, PF ;
SAMPIETRO, M ;
SPEZIALI, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (03) :467-478
[6]   AN OPTO-ELECTRONIC FEEDBACK PREAMPLIFIER FOR HIGH-RESOLUTION NUCLEAR SPECTROSCOPY [J].
GOULDING, FS ;
WALTON, J ;
MALONE, DF .
NUCLEAR INSTRUMENTS & METHODS, 1969, 71 (03) :273-&
[7]  
LANDIS DA, 1972, IEEE T NUCL SCI, V18, P115
[8]   A LOW-NOISE FET WITH INTEGRATED CHARGE RESTORATION FOR RADIATION DETECTORS [J].
NASHASHIBI, T ;
WHITE, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :452-456
[9]   THE PN-CCD ON-CHIP ELECTRONICS [J].
PINOTTI, E ;
BRAUNINGER, H ;
FINDEIS, N ;
GORKE, H ;
HAUFF, D ;
HOLL, P ;
KEMMER, J ;
LECHNER, P ;
LUTZ, G ;
KINK, W ;
MEIDINGER, N ;
METZNER, G ;
PREDEHL, P ;
REPPIN, C ;
STRUDER, L ;
TRUMPER, J ;
VONZANTHIER, C ;
KENDZIORRA, E ;
STAUBERT, R ;
RADEKA, V ;
REHAK, P ;
BERTUCCIO, G ;
GATTI, E ;
LONGONI, A ;
PULLIA, A ;
SAMPIETRO, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :85-91
[10]   SILICON DETECTOR SYSTEM FOR HIGH-RATE EXAFS APPLICATIONS [J].
PULLIA, A ;
KRANER, HW ;
SIDDONS, DP ;
FURENLID, LR ;
BERTUCCIO, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :585-589