A silica-based monolithic column in capillary HPLC and CEC coupled with ESI-MS or electrospray-atmospheric-pressure laser ionization-MS

被引:19
作者
Droste, S
Schellenträger, M
Constapel, M
Gäb, S
Lorenz, M
Brockmann, KJ
Benter, T
Lubda, D
Schmitz, OJ
机构
[1] Univ Wuppertal, Dept Analyt Chem, D-42119 Wuppertal, Germany
[2] Univ Wuppertal, Dept Phys Chem, D-42119 Wuppertal, Germany
[3] Merck KGaA, Prod Management MDA, Darmstadt, Germany
关键词
atmospheric-pressure laser ionization; CEC; mass spectrometry; monolithic column;
D O I
10.1002/elps.200500326
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe the successful coupling of CEC and capillary HPLC with the recently developed atmospheric-pressure laser ionization (APLI) method. APLI is suitable for selectively and sensitively ionizing nonpolar aromatic compounds at ambient pressure for subsequent mass-selective detection. The polycyclic aromatic hydrocarbons used as analytes are first separated either by CEC on a silica-based monolithic column or by capillary HPLC. The eluent, along with a sheath flow, is volatilized by microelectrospray and then selectively ionized by excimer laser (KrF*) radiation via two-photon excitation. A QTOF-MS is used as mass-selective detector. This interface combination makes soft ionization of thermally labile nonpolar aromatic analytes possible.
引用
收藏
页码:4098 / 4103
页数:6
相关论文
共 43 条
[1]   ION MOBILITY DETECTOR FOR GAS-CHROMATOGRAPHY WITH A DIRECT PHOTO-IONIZATION SOURCE [J].
BAIM, MA ;
EATHERTON, RL ;
HILL, HH .
ANALYTICAL CHEMISTRY, 1983, 55 (11) :1761-1766
[2]   State-of-the-art of the hyphenation of capillary electrochromatography with mass spectrometry [J].
Barceló-Barrachina, E ;
Moyano, E ;
Galceran, MT .
ELECTROPHORESIS, 2004, 25 (13) :1927-1948
[3]  
Bayer E, 1999, ANGEW CHEM INT EDIT, V38, P992, DOI 10.1002/(SICI)1521-3773(19990401)38:7<992::AID-ANIE992>3.0.CO
[4]  
2-K
[5]   Atmospheric-pressure laser ionization:: a novel ionization method for liquid chromatography/mass spectrometry [J].
Constapel, M ;
Schellenträger, M ;
Schmitz, OJ ;
Gäb, S ;
Brockmann, KJ ;
Giese, R ;
Benter, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (03) :326-336
[6]   Strategies for the liquid chromatographic-mass spectrometric analysis of non-polar compounds [J].
Hayen, H ;
Karst, U .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :549-565
[7]   LC-Electron capture APCI-MS for the determination of nitroaromatic compounds [J].
Hayen, H ;
Jachmann, N ;
Vogel, M ;
Karst, U .
ANALYST, 2002, 127 (08) :1027-1030
[8]   Detection and characterization of 20-oxosteroids in rat brains using LC-electron capture APCI-MS after derivatization with 2-nitro-4-trifluoromethylphenylhydrazine [J].
Higashi, T ;
Takido, N ;
Shimada, K .
ANALYST, 2003, 128 (02) :130-133
[9]   Electron-capturing derivatization of neutral steroids for increasing sensitivity in liquid chromatography/negative atmospheric pressure chemical ionization-mass spectrometry [J].
Higashi, T ;
Takido, N ;
Yamauchi, A ;
Shimada, K .
ANALYTICAL SCIENCES, 2002, 18 (12) :1301-1307
[10]  
HSIEY Y, 2003, ANAL CHEM, V75, P491