An integrated fritless column for on-chip capillary electrochromatography with conventional stationary phases

被引:121
作者
Ceriotti, L [1 ]
de Rooij, NF [1 ]
Verpoorte, E [1 ]
机构
[1] Univ Neuchatel, Inst Microtechnol, Sensors Actuators & Microsyst Lab, CH-2007 Neuchatel, Switzerland
关键词
D O I
10.1021/ac0109467
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new polymer device for use with conventional particulate stationary phases for on-chip, fritless, capillary electrochromatography (CEC) has been realized. The structure includes an injector and a tapered column in which the particles of the stationary phase are retained and stabilized. The chips were easily fabricated in poly(dimethylsiloxane) using deep-reactive-ion-etched silicon masters, and tested using a capillary electrophoretic separation of FITC-labeled amino acids. To perform CEC, the separation channel was packed using a vacuum with 3-mum, octadecylsilanized silica microspheres. The packing was stabilized in the column by a thermal treatment, and its stability and quality were evaluated using in-column indirect fluorescence detection. The effects of voltage on electro-osmotic flow and on efficiency were investigated, and the separation of two neutral compounds was achieved in less than 15 s.
引用
收藏
页码:639 / 647
页数:9
相关论文
共 109 条
[21]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[22]   Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays [J].
Dodge, A ;
Fluri, K ;
Verpoorte, E ;
de Rooij, NF .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3400-3409
[23]   Porous silicon as the carrier matrix in microstructured enzyme reactors yielding high enzyme activities [J].
Drott, J ;
Lindstrom, K ;
Rosengren, L ;
Laurell, T .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (01) :14-23
[24]   Microfabricated centrifugal microfluidic systems: Characterization and multiple enzymatic assays [J].
Duffy, DC ;
Gillis, HL ;
Lin, J ;
Sheppard, NF ;
Kellogg, GJ .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4669-4678
[25]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[26]   Preparation and characterization of monolithic porous capillary columns loaded with chromatographic particles [J].
Dulay, MT ;
Kulkarni, RP ;
Zare, RN .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :5103-5107
[27]  
Eckersten A, 2000, MESA MG, P521
[28]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[29]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[30]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457