Validation of a new automated method for analysis of gated-SPECT images

被引:16
作者
Lomsky, M
Richter, J
Johansson, L
Hoilund-Carlsen, PF
Edenbrandt, L [1 ]
机构
[1] Malmo Univ Hosp, Dept Clin Sci, SE-20502 Malmo, Sweden
[2] Sahlgrens Univ Hosp, Dept Clin Physiol, S-41345 Gothenburg, Sweden
[3] WeAidU Europe AB, Lund, Sweden
[4] Odense Univ Hosp, Dept Clin Physiol & Nucl Med, Odense, Denmark
关键词
computer-assisted diagnosis; gated-SPECT; heart disease; image processing; radionuclide imaging;
D O I
10.1111/j.1475-097X.2006.00667.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We recently presented a new method for quantification of CArdiac FUnction - denoted CAFU - as the first step in the development of an automated method for integrated interpretation of gated myocardial perfusion single photon emission computed tomography (SPECT) images. The aim of this study was to validate CAFU in the assessment of global and regional function of the left ventricle. Quantitative gated-SPECT (QGS), the most widely used software package for quantification of gated-SPECT images, was used as reference method for the measurements of ejection fraction (EF) and ventricular volumes, and visual analysis by an experienced physician was used as reference method for the measurements of regional wall motion and thickening. Two different groups of consecutive patients referred for myocardial perfusion scintigraphy were studied. Global function was evaluated in 316 patients and regional function in 49 other patients. The studies were performed using a 2-day stress/rest 99 m-Tc-sestamibi protocol. A good correlation was found between EF values from QGS and CAFU (EF CAFU = 0.84 EF QGS + 13, r = 0.94), but CAFU values were on average 4 EF points higher than QGS values. With CAFU the segments with normal thickening according to the physician showed significantly higher thickening values (in all parts of the myocardium) compared to the segments classified as having abnormal thickening. In conclusion, this study demonstrates that CAFU can be used to quantify global and regional function in gated-SPECT images. This is an important step in our development of an automated method for integrated interpretation of gated-SPECT myocardial perfusion scintigraphy studies.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 20 条
[1]   Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods [J].
Faber, TL ;
Vansant, JP ;
Pettigrew, RI ;
Galt, JR ;
Blais, M ;
Chatzimavroudis, G ;
Cooke, CD ;
Folks, RD ;
Waldrop, SM ;
Gurtler-Krawczynska, E ;
Wittry, MD ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (06) :645-651
[2]  
FICARO E, 2003, J NUCL CARDIOL, V10, pS23
[3]  
GERMANO G, 1995, J NUCL MED, V36, P2138
[4]  
Go V, 2004, J NUCL MED, V45, P912
[5]   Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging [J].
Johansen, A ;
Grupe, P ;
Veje, A ;
Braad, PEN ;
Hoilund-Carlsen, PF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (08) :1152-1159
[6]   Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET:: comparison with cardiac magnetic resonance imaging [J].
Lipke, CSA ;
Kühl, HP ;
Nowak, B ;
Kaiser, HJ ;
Reinartz, P ;
Koch, KC ;
Buell, U ;
Schaefer, WM .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (04) :482-490
[7]   A new automated method for analysis of gated-SPECT images based on a three-dimensional heart shaped model [J].
Lomsky, M ;
Richter, J ;
Johansson, L ;
El-Ali, H ;
Åström, K ;
Ljungberg, M ;
Edenbrandt, L .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2005, 25 (04) :234-240
[8]   Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT [J].
Lum, DP ;
Coel, MN .
NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (03) :259-266
[9]  
Matsumoto N, 2001, J NUCL MED, V42, P687
[10]  
Nakajima K, 2001, J NUCL MED, V42, P1571