Multi-detector row CT angiography of the brain at various kilovoltage settings

被引:89
作者
Ertl-Wagner, BB
Hoffmann, RT
Bruning, R
Herrmann, K
Snyder, B
Blume, JD
Reiser, MF
机构
[1] Univ Munich, Klinikum Grosshadern, Inst Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Dept Neuroradiol, D-81377 Munich, Germany
[3] Brown Univ, Ctr Stat Sci, Providence, RI 02912 USA
关键词
brain; CT; computed tomography (CT); image quality; multi-detector row;
D O I
10.1148/radiol.2312030543
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate image quality and vascular delineation of multi-detector row computed tomographic (CT) angiography at various kilovoltage Settings. MATERIALS AND METHODS: Thirty patients were investigated with a standardized CT protocol, with three groups of 10 consecutive patients examined at 80, 120, and 140 kV, respectively. Three blinded readers independently evaluated images and graded image quality parameters, diagnostic confidence, and vascular delineation of intracranial arteries and veins. Vascular CT attenuation values, CT dose indices, and dose length products were assessed quantitatively. For data analysis, a Kruskal-Wallis nonparametric rank F test was used to identify trends and variables that required modeling attention. A proportional odds multinomial regression model was then fit with generalized estimating equations to account for the correlated nature of the data. RESULTS: Image quality was rated higher with higher kilovoltage settings (P < .001). The severity of imaging artifacts was higher with lower kilovoltage settings g g (P < .001), while the subjectively rated vessel contrast was lower in the 80-kV group than in the 120-kV group and the 140-kV group (P < .05). Diagnostic confidence was higher in the 120-kV group and 140-kV group (P < .005). Vascular delineation was higher with higher kilovoltage settings for most arterial and venous structures. Differences were more significant for structures in close topographic proximity to bone and for subsegmental arteries and were less significant and, in parts, not significant for the main arterial branches and the large venous sinus. Attenuation values were higher with lower kilovoltage settings (P < .05). The mean dose length product could be reduced from 594 mGy . cm in the 140-kV group to 152 mGy (.) cm in the 80-kV group. CONCLUSION: This multireader study of image quality and vessel delineation with cranial multi-detector row CT angiography at various kilovoltage settings demonstrated a superiority of higher voltages with most pronounced effects for vessels adjacent to bone and subsegmental arteries. (C) RSNA, 2004.
引用
收藏
页码:528 / 535
页数:8
相关论文
共 19 条
  • [11] Assessment of the arteriovenous cerebrovascular system by multi-slice CT -: A single-bolus, monophasic protocol
    Klingebiel, R
    Zimmer, C
    Rogalla, P
    Kivelitz, D
    Bohner, G
    Götze, R
    Lehmann, R
    [J]. ACTA RADIOLOGICA, 2001, 42 (06) : 560 - 562
  • [12] MCCULLOUGH E C, 1975, Medical Physics (Woodbury), V2, P307, DOI 10.1118/1.594199
  • [13] Standard-dose and 50%-reduced-dose chest CT: Comparing the effect on image quality
    Prasad, SR
    Wittram, C
    Shepard, JA
    McLoud, T
    Rhea, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (02) : 461 - 465
  • [14] Radiation exposure and image quality in chest CT examinations
    Ravenel, J
    Scalzetti, EM
    Huda, W
    Garrisi, W
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) : 279 - 284
  • [15] MEASUREMENT OF EFFECTIVE ATOMIC NUMBER AND ELECTRON-DENSITY USING AN EMI SCANNER
    RUTHERFORD, RA
    PULLAN, BR
    ISHERWOOD, I
    [J]. NEURORADIOLOGY, 1976, 11 (01) : 15 - 21
  • [16] The effect of decreasing mAs on image quality and patient dose in sinus CT
    Sohaib, SA
    Peppercorn, PD
    Horrocks, JA
    Keene, MH
    Kenyon, GS
    Reznek, RH
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (878) : 157 - 161
  • [17] Multirow detector and cone-beam spiral/helical CT
    Wang, G
    Crawford, CR
    Kalender, WA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 817 - 821
  • [18] Wintermark M, 2000, AM J NEURORADIOL, V21, P1881
  • [19] EFFECT OF KVP LEVEL ON EMI VALUES - SELECTIVE IMAGING OF VARIOUS MATERIALS WITH DIFFERENT KVP SETTINGS
    ZATZ, LM
    [J]. RADIOLOGY, 1976, 119 (03) : 683 - 688