Preparation of functionalized copper nanoparticles and fabrication of a glucose sensor

被引:194
作者
Xu, Q [1 ]
Zhao, Y [1 ]
Xu, JZ [1 ]
Zhu, JJ [1 ]
机构
[1] Nanjing Univ, Dept Chem, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
基金
中国国家自然科学基金;
关键词
copper nanoparticles; dimethylglycoxime; glucose;
D O I
10.1016/j.snb.2005.06.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dimethylglycoxime, (DMG) functionalized copper nanoparticles (DMG-CuNPs) were prepared by a microwave heating method and characterized by TEM, FTIR, and XRD. The as-prepared nanoparticles were used to construct a new glucose sensor. Experimental results showed that DMG could be used to encapsulate the copper nanoparticles to control their growth during the preparation process and could chelate copper ions which were produced during the positive scan in the electrochemical experiments. The sensor showed good selectivity and sensitivity. A wide linearity range and a low detection limit have been assessed for it. A linear response to glucose in the concentration range between 1.0 X 10(-6) and 5.0 x 10(-3) M and a detection limit of 5.0 x 10(-7) M were observed. Most important of all, the common drawback of copper electrode fouling was overcome in this sensor. (c) 2005 Elsevier B.V. All righis reserved.
引用
收藏
页码:379 / 386
页数:8
相关论文
共 38 条
[1]   SYNTHESES, REDOX BEHAVIOR, AND MAGNETIC AND SPECTROSCOPIC PROPERTIES OF CUIICUIICUII, CUIINIIICUII, AND CUIIPDIICUII SPECIES - CRYSTAL-STRUCTURE OF [L2CU2CU(DMG)2BR]CLO4.CH3OH (L=1,4,7-TRIMETHYL-1,4,7-TRIAZACYCLONONANE-DMG=DIMETHYLGLYOXIMATO(2-)) [J].
CHAUDHURI, P ;
WINTER, M ;
DELLAVEDOVA, BPC ;
BILL, E ;
TRAUTWEIN, A ;
GEHRING, S ;
FLEISCHHAUER, P ;
NUBER, B ;
WEISS, J .
INORGANIC CHEMISTRY, 1991, 30 (09) :2148-2157
[2]   Development and characterization of microfabricated disposable gold working electrodes for high-performance ion chromatography and integrated pulsed amperometric detection [J].
Cheng, J ;
Jandik, P ;
Avdalovic, N .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :572-579
[3]  
CLARKE SG, 1929, ANALYST, V54, P333
[4]   A disposable amperometric sensor screen printed on a nitrocellulose strip: A glucose biosensor employing lead oxide as an interference-removing agent [J].
Cui, G ;
Kim, SJ ;
Choi, SH ;
Nam, H ;
Cha, GS ;
Paeng, KJ .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1925-1929
[5]  
D 'Eramo F, 1999, ELECTROANAL, V11, P481, DOI 10.1002/(SICI)1521-4109(199906)11:7<481::AID-ELAN481>3.0.CO
[6]  
2-7
[7]   COBALT PORPHYRIN NAFION FILM ON CARBON MICROARRAY ELECTRODE TO MONITOR OXYGEN FOR ENZYME ANALYSIS OF GLUCOSE [J].
DONG, S ;
KUWANA, T .
ELECTROANALYSIS, 1991, 3 (06) :485-491
[8]  
Dou YH, 2002, ELECTROPHORESIS, V23, P3558, DOI 10.1002/1522-2683(200210)23:20<3558::AID-ELPS3558>3.0.CO
[9]  
2-#
[10]   Anomalously increased effective thermal conductivities of ethylene glycol-based nanofluids containing copper nanoparticles [J].
Eastman, JA ;
Choi, SUS ;
Li, S ;
Yu, W ;
Thompson, LJ .
APPLIED PHYSICS LETTERS, 2001, 78 (06) :718-720