Double echo steady state magnetic resonance imaging of knee articular cartilage at 3 Tesla: a pilot study for the Osteoarthritis Initiative

被引:241
作者
Eckstein, F
Hudelmaier, M
Wirth, W
Kiefer, B
Jackson, R
Yu, J
Eaton, CB
Schneider, E
机构
[1] PMU, Inst Anat & Musculoskeletal Res, A-5020 Salzburg, Austria
[2] Chondrometr GmbH, Ainring, Germany
[3] Siemens Med Solut, MR Applicat Dev, Erlangen, Germany
[4] Ohio State Univ, Dept Diabet Endocrinol & Metab, Columbus, OH 43210 USA
[5] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
[6] Brown Univ, Sch Med, Pawtucket, RI USA
[7] Brown Univ, Mem Hosp Rhode Isl, Ctr Primary Care & Prevent, Pawtucket, RI 02860 USA
[8] SciTrials LLC, Westwood, MA USA
关键词
D O I
10.1136/ard.2005.039370
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Quantitative magnetic resonance imaging (qMRI) may provide valuable measures of cartilage morphology in osteoarthritis (OA) but has been confined to sequences with relatively long acquisition times at 1.5 Tesla (T). Objective: To test the accuracy and precision of knee cartilage qMRI with a fast double echo, steady state ( DESS) sequence with water excitation (we) at 3 T. Methods: As a pilot study for the Osteoarthritis Initiative, test-retest MR images were acquired in the knees of 19 participants with no OA to moderate degrees of clinical OA. Two double oblique coronal fast low angle shot (FLASHwe) sequences (1.5 mm slice thickness) were acquired at 3 T, and two sagittal DESSwe sequences (0.7 mm slice thickness). Double oblique coronal multiplanar reformats (MPR) were performed (1.5 mm slice thickness) from the sagittal DESSwe. Knee joint cartilage plates were quantified unpaired in random order with blinding to subject identification. Results: In the femorotibial joint, precision errors (root mean square coefficient of variation in % for unpaired analysis) for cartilage volume and thickness were 3.0-6.4% with coronal FLASHwe, 2.4-6.2% with coronal MPR DESSwe, and 2.3-8.2% with sagittal DESSwe. Correlation coefficients between DESSwe and FLASHwe ranged from r = 0.88 to 1.0. In the femoropatellar joint, precision errors (sagittal DESSwe) were 3.4-8.5%. Conclusions: DESSwe permits accurate and precise analysis of cartilage morphology in the femorotibial joint at 3 T. Further studies are needed to examine the accuracy of DESSwe in the femoropatellar joint and its ability to characterise sensitivity to longitudinal changes in cartilage morphology.
引用
收藏
页码:433 / 441
页数:9
相关论文
共 22 条
  • [11] ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES
    GLUER, CC
    BLAKE, G
    LU, Y
    BLUNT, BA
    JERGAS, M
    GENANT, HK
    [J]. OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) : 262 - 270
  • [12] Quantitative assessment of cartilage status in osteoarthritis by quantitative magnetic resonance imaging - Technical validation for use in analysis of cartilage volume and further morphologic parameters
    Graichen, H
    Von Eisenhart-Rothe, R
    Vogl, T
    Englmeier, KH
    Eckstein, F
    [J]. ARTHRITIS AND RHEUMATISM, 2004, 50 (03): : 811 - 816
  • [13] Gray M L, 2001, Semin Musculoskelet Radiol, V5, P329, DOI 10.1055/s-2001-19043
  • [14] Toward imaging biomarkers for osteoarthritis
    Gray, ML
    Eckstein, F
    Peterfy, C
    Dahlberg, L
    Kim, YJ
    Sorensen, AG
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (427) : S175 - S181
  • [15] Optimization of a dual echo in the steady state (DESS) free-precession sequence for imaging cartilage
    Hardy, PA
    Recht, MP
    Piraino, D
    Thomasson, D
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (02): : 329 - 335
  • [16] Cartilage atrophy in the knees of patients after seven weeks of partial load bearing
    Hinterwimmer, S
    Krammer, M
    Krötz, M
    Glaser, C
    Baumgart, R
    Reiser, M
    Eckstein, F
    [J]. ARTHRITIS AND RHEUMATISM, 2004, 50 (08): : 2516 - 2520
  • [17] Mosher TJ, 1999, J MAGN RESON IMAGING, V10, P178, DOI 10.1002/(SICI)1522-2586(199908)10:2<178::AID-JMRI11>3.0.CO
  • [18] 2-W
  • [19] Peterfy C G, 2001, Semin Musculoskelet Radiol, V5, P365, DOI 10.1055/s-2001-19045
  • [20] Peterfy C G, 2000, Magn Reson Imaging Clin N Am, V8, P409