Design and fabrication of a microelectrode array for iodate quantification in small sample volumes

被引:26
作者
Lowinsohn, D
Peres, HEM
Kosminsky, L
Paixao, TRLC
Ferreira, TL
Ramirez-Fernandez, FJ
Bertotti, M [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05508900 Sao Paulo, Brazil
[2] Univ Sao Paulo, SIM Grp, Microelect Lab, Escola Politecn, BR-05508900 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
voltammetry; electrodeposition; microelectrode;
D O I
10.1016/j.snb.2005.02.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the simple manufacture of microelectrode arrays is described The construction technique is based on microelectronics technology by conventional sputtering deposition of layers of Ni/Cr and An. photolithography and a linal treatment to improve the chemical stability of the device. Cyclic voltammetry at both sulphuric acid and ferricyanide solutions was employed to inspect the operation of the microelectrodes. which can be individually addressable. This microelectrode has been used successfully for indirect amperometric measurements of the iodate content in very small volumes (typically 50-200 mu I) of solutions prepared front the dissolution of commercial Brazilian salt samples, which illustrates its potentiality as useful tools in electroanalytical chemistry. The possibility of modifying the surface of the gold microelectrodes by electrodeposition of molybdenum oxides was also investigated. The results indicated that the device can also be used as a practical sensor for measuring directly iodate owing to the cohancement of the reduction signal by in electrocatalytic process. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 51 条
[1]   COMBINING MICROMACHINING AND MOLECULAR SELF-ASSEMBLY TO FABRICATE MICROELECTRODES [J].
ABBOTT, NL ;
ROLISON, DR ;
WHITESIDES, GM .
LANGMUIR, 1994, 10 (08) :2672-2682
[2]  
ADAMS RN, 1969, ELECTROCHEMISTRY SOL, P215
[3]   Gold electrodes from recordable CDs [J].
Angnes, L ;
Richter, EM ;
Augelli, MA ;
Kume, GH .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5503-5506
[4]   Flow-through cell based on an array of gold microelectrodes obtained from modified integrated circuit chips [J].
Augelli, MA ;
Nascimento, VB ;
Pedrotti, JJ ;
Gutz, IGR ;
Angnes, L .
ANALYST, 1997, 122 (08) :843-847
[5]   Independent geometrical and electrochemical characterization of arrays of nanometer-scale electrodes [J].
Baker, WS ;
Crooks, RM .
JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (49) :10041-10046
[6]   DIGITAL-SIMULATION OF THE MEASURED ELECTROCHEMICAL RESPONSE OF REVERSIBLE REDOX COUPLES AT MICROELECTRODE ARRAYS - CONSEQUENCES ARISING FROM CLOSELY SPACED ULTRAMICROELECTRODES [J].
BARD, AJ ;
CRAYSTON, JA ;
KITTLESEN, GP ;
SHEA, TV ;
WRIGHTON, MS .
ANALYTICAL CHEMISTRY, 1986, 58 (11) :2321-2331
[7]   The reduction of bromate at molybdenum oxide film cathodes [J].
Bertotti, M ;
Pletcher, D .
ELECTROANALYSIS, 1996, 8 (12) :1105-1111
[8]   Amperometric determination of nitrite via reaction with iodide using microelectrodes [J].
Bertotti, M ;
Pletcher, D .
ANALYTICA CHIMICA ACTA, 1997, 337 (01) :49-55
[10]   Modifications and characterization of a silicon-based microelectrode array [J].
Buss, G ;
Schöning, MJ ;
Lüth, H ;
Schultze, JW .
ELECTROCHIMICA ACTA, 1999, 44 (21-22) :3899-3910