Electrooxidation of Nitrite Mediated by Cu-x-Tetraaminophenylporphyrin (x=2, 3, and 4) Glassy Carbon-Modified Electrodes: Effect of Substituent Position

被引:14
作者
Camargo, Andres [1 ]
Aguirre, Maria J. [2 ]
Cheuquepan, William [2 ]
Chen, Yo-Ying [2 ]
Ramirez, Galo [1 ]
机构
[1] Univ Andres Bello, Fac Ecol & Recursos Nat, Dept Ciencias Quim, Santiago, Chile
[2] Univ Santiago Chile, Fac Quim Biol, Dept Quim Mat, Santiago, Chile
关键词
Nitrite oxidation; Nitrite amperometric sensor; Modified electrode; Cu tetraaminophenyl porphyrin;
D O I
10.1002/elan.200804369
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A study of glassy carbon electrodes modified with poly-Cu-x-tetraaminophenylporphyrin (TAPP) (x=2, 3, and 4) toward the electrooxidation of nitrite is reported. The position of the amino group influences the degree of electropolymerization and the response toward the electrooxidation of nitrite. The influence of pH on the electrocatalytic oxidation of nitrite was also studied, finding that the activity is strongly pH-dependent. For each system (polymeric porphyrins, poly-Cu-2-TAPP, poly-Cu-3-TAPP, and poly-Cu-4-TAPP), the behavior of the modified electrode as amperometric nitrite sensor was studied at the best pH response, finding a linear correlation over a wide range of concentrations for Poly-Cu-3-TAPP. With poly-Cu-2-TAPP, the range is smaller, and there is no linear relationship for poly-Cu-4-TAPP. The plot of I-p vs. the square root of the scan rate shows a linear relationship for all the polymer systems, indicating that the electrooxidation of nitrite in the modified electrodes is a process controlled by diffusion. The Tafel slope was calculated, indicating that the determining step in the electrooxidation of nitrite varies depending on the position of the substituent, showing a dramatic change in the nature of the active sites.
引用
收藏
页码:2635 / 2641
页数:7
相关论文
共 40 条
[1]   Micell-mediated extraction for the spectrophotometric determination of nitrite in water and biological samples based on its reaction with p-nitroaniline in the presence of diphenylamine [J].
Afkhami, A ;
Bahram, M ;
Gholami, S ;
Zand, Z .
ANALYTICAL BIOCHEMISTRY, 2005, 336 (02) :295-299
[2]   THE DETERMINATION OF NITRATE IN CURED MEAT-PRODUCTS - A COMPARISON OF THE HPLC UV/VIS AND CD/SPECTROPHOTOMETRIC METHODS [J].
ALONSO, A ;
ETXANIZ, B ;
MARTINEZ, MD .
FOOD ADDITIVES AND CONTAMINANTS, 1992, 9 (02) :111-117
[3]   Electrocatalytic reduction of nitrate ion on Cu and Ni poly-tetraaminophenylporphyrin-modified electrodes [J].
Armijo, F ;
Isaacs, M ;
Ramírez, G ;
Trollund, E ;
Canales, J ;
Aguirre, MJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 566 (02) :315-322
[4]   Electrocatalytic oxidation of nitrite to nitrate mediated by Fe(III) poly-3-aminophenyl porphyrin grown on five different electrode surfaces [J].
Armijo, Francisco ;
Goya, Ma Carmen ;
Reina, Matias ;
Canales, M. Josefina ;
Arevalo, Ma Carmen ;
Aguirre, Ma Jesus .
JOURNAL OF MOLECULAR CATALYSIS A-CHEMICAL, 2007, 268 (1-2) :148-154
[5]   A novel method for the spectrophotometric determination of nitrite in water [J].
Aydin, A ;
Ercan, Ö ;
Tascioglu, S .
TALANTA, 2005, 66 (05) :1181-1186
[6]   Design and characterization of chemically modified electrodes with iron(III) porphyrinic-based polymers: Study of their reactivity toward nitrites and nitric oxide in aqueous solution [J].
Bedioui, F ;
Trevin, S ;
Albin, V ;
Villegas, MGG ;
Devynck, J .
ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) :177-185
[7]   Synthesis and characterization of polymeric films and nanotubule nets used to assemble selective sensors for nitrite detection in drinking water [J].
Biagiotti, Vanessa ;
Valentini, Federica ;
Tamburri, Emanuela ;
Terranova, Maria Letizia ;
Moscone, Danila ;
Palleschi, Giuseppe .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) :236-242
[8]   Simple flow-injection system for the simultaneous determination of nitrite and nitrate in water samples [J].
Burakham, R ;
Oshima, M ;
Grudpan, K ;
Motomizu, S .
TALANTA, 2004, 64 (05) :1259-1265
[9]   Electrocatalytic oxidation of nitrite on a carbon paste electrode modified with Co(II) porphyrin adsorbed on SiO2/SnO2/phosphate prepared by the sol-gel method [J].
Cardoso, WS ;
Gushikem, Y .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 583 (02) :300-306
[10]   Experimental and theoretical study of the activity of substituted metallophthalocyanines for nitrite electro-oxidation [J].
Caro, CA ;
Bedioui, F ;
Páez, MA ;
Cárdenas-Jiron, GI ;
Zagal, JH .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2004, 151 (01) :E32-E39