An immunomagnetic electrochemical sensor based an a perfluorosulfonate-coated screen-printed electrode for the determination of 2,4-dichlorophenoxyacetic acid

被引:66
作者
Dequaire, M [1 ]
Degrand, C [1 ]
Limoges, B [1 ]
机构
[1] Univ Blaise Pascal, CNRS, UMR 6504, F-63177 Clermont Ferrand, France
关键词
D O I
10.1021/ac990101j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable immunomagnetic electrochemical sensor involving a magnetic particle-based solid phase and a Nafion film-coated screen-printed electrode (Nafion-SPE) stuck at the bottom of a polystyrene cylinder (microwell of 300 mu L) was developed and evaluated in a competitive immunoassay of the widely used herbicide 2,4-dichlorophenoxyacetic acid (2,4-D). The competitive binding of 2,4-D and 2,4-D labeled with alkaline phosphatase (AP) for a limited amount of polyclonal anti-2,4-D antibody-coated magnetic beads was monitored electrochemically by measuring the AP label activity bound to the beads. The phosphoric acid ester of [[(4-hydroxyphenyl)amino]carbonyl]cobaltocenium hexafluorophosphate was used as the AP substrate. This anionic substrate (S-) is enzymatically transformed at pH 9.0 into a cationic phenol derivative (pf) which can be easily accumulated in the polyanionic Nafion coating and determined by cyclic voltammetry. During the enzyme reaction, the AP-associated beads were localized on the surface of the Nafion-SPE with the aid of a magnet, thus effectively increasing the concentration of P+ in the Nafion-modified electrode vicinity. The enzyme generation of pf close to the electrode surface, and thereby to the Nafion film, resulted in a high amplification of the response. A detection limit of 0.01 mu g L-1 2,4-D was thus achieved. The performance of the sensor was successfully evaluated on river water samples spiked with 2,4-D, indicating that this convenient and sensitive technique offers great promise for decentralized environmental applications.
引用
收藏
页码:2571 / 2577
页数:7
相关论文
共 49 条
[41]   Advances in electrochemical immunosensors [J].
Skladal, P .
ELECTROANALYSIS, 1997, 9 (10) :737-745
[42]   Flow injection immunoanalysis based on a magnetoimmunosensor system [J].
Solé, S ;
Alegret, S ;
Céspedes, F ;
Fàbregas, E ;
Díez-Caballero, T .
ANALYTICAL CHEMISTRY, 1998, 70 (08) :1462-1467
[43]   IMMUNOCHEMICAL METHODS - FOR ENVIRONMENTAL-ANALYSIS [J].
VANEMON, JM ;
LOPEZAVILA, V .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :A79-A88
[44]   Sol-gel-derived thick-film amperometric immunosensors [J].
Wang, J ;
Pamidi, PVA ;
Rogers, KR .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1171-1175
[45]   Thick film electrochemical immunosensor based on stripping potentiometric detection of a metal ion label [J].
Wang, J ;
Tian, BM ;
Rogers, KR .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1682-1685
[46]  
WEETALL HH, 1987, BIOSENSORS, V3, P57
[47]   DEVELOPMENT OF AN ELISA FOR THE ANALYSIS OF ATRAZINE METABOLITES DEETHYLATRAZINE AND DEISOPROPYLATRAZINE [J].
WITTMANN, C ;
HOCK, B .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (06) :1194-1200
[48]   Comparative studies of magnetic particle-based solid phase fluorogenic and electrochemiluminescent immunoassay [J].
Yu, H .
JOURNAL OF IMMUNOLOGICAL METHODS, 1998, 218 (1-2) :1-8
[49]   Development of a magnetic microplate chemifluorimmunoassay for rapid detection of bacteria and toxin in blood [J].
Yu, H ;
Ahmed, H ;
Vasta, GR .
ANALYTICAL BIOCHEMISTRY, 1998, 261 (01) :1-7