A trigger channel threshold artifact in nanoparticle analysis

被引:63
作者
Nolan, John P. [1 ]
Stoner, Samuel A. [1 ]
机构
[1] La Jolla Bioengn Inst, La Jolla, CA 92037 USA
关键词
flow cytometry; microparticle; microvesicle; exosome; ectosome; vesicle; light scatter; fluorescence; CELL-DERIVED MICROPARTICLES; FLOW-CYTOMETRY; CIRCULATING MICROPARTICLES; STANDARDIZATION; COINCIDENCE; IMPACT;
D O I
10.1002/cyto.a.22255
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
The analysis of individual nanoparticles by flow cytometry involves the measurement of dim signals that are near the detection limits of the instrument. Discriminating the signal from particles of interest from that of background particles in buffers and from optical and electronic noise can be challenging, and requires careful consideration of the measurement approach, control experiments, and scrutiny of the resulting data. In applying this scrutiny, we have come to recognize an artifact that results from the inappropriate selection of the trigger channel threshold that might not be obvious to the casual user. When measuring dim signals close to the noise or background levels, it is intuitive and common for the operator to adjust the trigger threshold to minimize the false triggers acquired by the system, and then to run the unknown sample, interpreting the events detected above the background as measurements of individual particles. We show here that when this approach is used to measure particles whose signals fall below the trigger threshold, only coincident events are detected, producing erroneous measurements of both particle number and brightness. We suggest that in many cases, the analysis of dim nanoparticles is best achieved using a fluorescence channel for the trigger. (c) 2013 International Society for Advancement of Cytometry
引用
收藏
页码:301 / 305
页数:5
相关论文
共 12 条
[1]
[Anonymous], 1998, ABSORPTION SCATTERIN
[2]
Measurement of circulating cell-derived microparticles by flow cytometry: Sources of variability within the assay [J].
Ayers, Lisa ;
Kohler, Malcolm ;
Harrison, Paul ;
Sargent, Ian ;
Dragovic, Rebecca ;
Schaap, Marianne ;
Nieuwland, Rienk ;
Brooks, Susan A. ;
Ferry, Berne .
THROMBOSIS RESEARCH, 2011, 127 (04) :370-377
[3]
A new microparticle size calibration standard for use in measuring smaller microparticles using a new flow cytometer [J].
Chandler, W. L. ;
Yeung, W. ;
Tait, J. F. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (06) :1216-1224
[4]
Detection of circulating microparticles by flow cytometry: influence of centrifugation, filtration of buffer, and freezing [J].
Dey-Hazra, Emily ;
Hertel, Barbara ;
Kirsch, Torsten ;
Woywodt, Alexander ;
Lovric, Svjetlana ;
Haller, Hermann ;
Haubitz, Marion ;
Erdbruegger, Uta .
VASCULAR HEALTH AND RISK MANAGEMENT, 2010, 6 :1125-1133
[5]
Impact of coincidence on granulocyte-platelet complex determination by flow cytometry is evaluated by a novel computer simulation model of coincidence [J].
Fent, Janos ;
Bihari, Peter ;
Furesz, Jozsef ;
Hamar, Janos ;
Lakatos, Susan .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2008, 70 (06) :1086-1090
[6]
Measuring circulating cell-derived microparticles [J].
Jy, W ;
Horstman, LL ;
Jimenez, JJ ;
Ahn, YS .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2004, 2 (10) :1842-1851
[7]
COINCIDENCE IN HIGH-SPEED FLOW-CYTOMETRY - MODELS AND MEASUREMENTS [J].
KEIJ, JF ;
VANROTTERDAM, A ;
GROENEWEGEN, AC ;
STOKDIJK, W ;
VISSER, JWM .
CYTOMETRY, 1991, 12 (05) :398-404
[8]
Impact of pre-analytical parameters on the measurement of circulating microparticles: towards standardization of protocol [J].
Lacroix, R. ;
Judicone, C. ;
Poncelet, P. ;
Robert, S. ;
Arnaud, L. ;
Sampol, J. ;
Dignat-George, F. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2012, 10 (03) :437-446
[9]
Standardization of platelet-derived microparticle enumeration by flow cytometry with calibrated beads: results of the International Society on Thrombosis and Haemostasis SSC Collaborative workshop [J].
Lacroix, R. ;
Robert, S. ;
Poncelet, P. ;
Kasthuri, R. S. ;
Key, N. S. ;
Dignat-George, F. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (11) :2571-2574
[10]
Flow Cytometric Analysis of Circulating Microparticles in Plasma [J].
Orozco, Aaron F. ;
Lewis, Dorothy E. .
CYTOMETRY PART A, 2010, 77A (06) :502-514