Percutaneous MR imaging-guided transvascular access of mesenteric venous system: Study in swine model

被引:12
作者
Arepally, A
Karmarkar, PV
Weiss, C
Atalar, E
机构
[1] Johns Hopkins Med Inst, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Bilkent Univ, Dept Elect & Elect Engn, Ankara, Turkey
关键词
D O I
10.1148/radiol.2381041533
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To determine if, with use of magnetic resonance (MR) imaging guidance alone, transcaval puncture of the superior mesenteric vein (SMV) and/or portal vein is feasible with a percutaneous femoral vein approach. Materials and Methods: The Institutional Animal Care and Use Committee approved the animal studies. Ten inferior vena cava (IVC) SMV punctures were performed in six pigs. An active MR intravascular needle system was used for all transvascular punctures, and all procedures were performed with a 1.5-T MR unit. The needle was introduced via a 12-F femoral vein sheath and advanced into the IVC by using a real-time gradient-recalled-echo sequence (3.4/1.2 [repetition time msec/echo time msec], 45 flip angle, and six to eight frames per second). Fast transverse spoiled gradient-recalled acquisition in the steady state (SPGR) (6.0/1.5, 60 flip angle, one frame per second) was performed to confirm needle trajectory. The needle system was advanced under real-time MR imaging to puncture the SMV. The location of the needle tip was confirmed with a fast spin-echo sequence (1904/4.5, 36-cm field of view). A direct MR portogram was obtained after the administration of gadopentetate dimeglumine at a concentration of 25% with fast SPGR (6/1.3, 90 flip angle, no section selection, three frames per second). Success was defined as entry into the mesenteric venous system without traversal of any retroperitoneal organs or adjacent vasculature. Results: Successful MR imaging-guided IVC-SMV punctures were performed in all 10 procedures (100%). The needle was fully visualized as it traversed the retroperitoneum and entered the SMV. MR portograms were successfully obtained following all punctures through the needle. Conventional transverse MR imaging helped confirm that the needle did not traverse any retroperitoneal organs or vessels. Conclusion: With use of only MR imaging guidance and an active MR imaging intravascular needle system, the authors were able to successfully puncture the SMV from the IVC with direct visualization of the needle and all retroperitoneal structures. (c) RSNA, 2006.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 8 条
[1]
Catheter-tracking FOV MR fluoroscopy [J].
Atalar, E ;
Kraitchman, DL ;
Carkhuff, B ;
Lesho, J ;
Ocali, O ;
Solaiyappan, M ;
Guttman, MA ;
Charles, HK .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :865-872
[2]
Percutaneous retroperitoneal splenorenal shunt:: An experimental study in swine [J].
Kaminou, T ;
Rösch, J ;
Yamada, R ;
Uchida, BT ;
Pavcnik, D ;
Timmermans, HA ;
Sakaguchi, S ;
Keller, FS .
RADIOLOGY, 1998, 206 (03) :799-802
[3]
Real-time magnetic resonance imaging: Diagnostic and interventional applications [J].
Lardo, AC .
PEDIATRIC CARDIOLOGY, 2000, 21 (01) :80-98
[4]
Portacaval space anatomy: Potential implications for percutaneous portacaval shunts [J].
McLoughlin, RF ;
Rankin, RN .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (05) :761-767
[5]
Intravascular magnetic resonance imaging using a loopless catheter antenna [J].
Ocali, O ;
Atalar, E .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :112-118
[6]
Real-time projection MR angiography: Feasibility study [J].
Serfaty, JM ;
Atalar, E ;
Declerck, J ;
Karmakar, P ;
Quick, HH ;
Shunk, KA ;
Heldman, AW ;
Yang, XM .
RADIOLOGY, 2000, 217 (01) :290-295
[7]
Percutaneous extrahepatic portacaval shunt with covered prostheses:: Feasibility study [J].
Vivas, I ;
Bilbao, JI ;
Martínez-Cuesta, A ;
Benito, A ;
Sola, JJ ;
Delgado, C ;
Espí, AR .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (12) :1543-1552
[8]
RF safety of wires in interventional MRI: Using a safety index [J].
Yeung, CJ ;
Susil, RC ;
Atalar, E .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :187-193