Automatic sequential injection liquid-liquid micro-extraction system for on-line flame atomic absorption spectrometric determination of trace metal in water samples

被引:46
作者
Anthemidis, Aristidis N. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
关键词
Lead; Sequential injection; Liquid-liquid extraction; Atomic absorption spectrometry;
D O I
10.1016/j.talanta.2008.04.017
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
An automatic sequential injection (SI) liquid-liquid micro-extraction system incorporating a dual-conical micro-gravitational phase separator is proposed as versatile approach for on-line metal preconcentration and/or separation. Coupled to flame atomic absorption spectrometry (FAAS) the potentials of this novel schema are demonstrated for lead determination in water samples at the mu gl(-1) level. The non-charged lead complex with ammonium pyrrolidine dithiocarbamate (APDC) was extracted on-line into 300 W isobutyl methyl ketone (IBMK) through the extraction coil. The organic phase containing the extracted metal complex is collected in the upper cavity of the phase separator and then forwarded to the nebulizer. All the Critical parameters were optimized and offered good performance Characteristics and high preconcentration ratios. A sample consumption of 10.5 ml enabled the determination of Pb(II) in the range of 3.0-250.0 mu gl(-1) with an enhancement factor of 120 and a sampling frequency of 25 h(-1). The detection limit and the precision were 1.4 mu gl(-1) and 2.9% (at 50.0 mu gl(-1) concentration level), respectively. The Proposed method was evaluated by analyzing certified reference material and was applied Successfully to the analysis of natural water samples. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:541 / 545
页数:5
相关论文
共 21 条
[1]
On-line liquid-liquid extraction system using a new phase separator for flame atomic absorption spectrometric determination of ultra-trace cadmium in natural waters [J].
Anthemidis, AN ;
Zachariadis, GA ;
Farastelis, CG ;
Stratis, JA .
TALANTA, 2004, 62 (03) :437-443
[2]
Development of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (11) :1400-1403
[3]
APHA AWWA WEF, 1995, STAND METH EX WAT WA
[4]
CONTINUOUS SOLVENT-EXTRACTION IN A CLOSED-LOOP SYSTEM [J].
ATALLAH, RH ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2909-2914
[5]
DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[6]
Determination of Fe(III) and total Fe in wines by sequential injection analysis and flame atomic absorption spectrometry [J].
Costa, RCD ;
Araújo, AN .
ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) :227-233
[7]
Fang Z., 1995, FLOW INJECTION ATOMI
[8]
Trends of flow injection sample pretreatment approaching the new millennium [J].
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1999, 400 :233-247
[9]
Use of flow injection and sequential injection analysis schemes for the determination of trace-level concentrations of metals in complex matrices by ETAAS and ICPMS [J].
Hansen, EH .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2005, 40 (08) :1507-1524
[10]
Sequential injection analysis [J].
Lenehan, CE ;
Barnett, NW ;
Lewis, SW .
ANALYST, 2002, 127 (08) :997-1020