Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces

被引:140
作者
Huber, Monika [1 ]
Reinisch, Georg [2 ]
Trettenhahn, Guenter [3 ]
Zweymueller, Karl [4 ]
Lintner, Felix [1 ]
机构
[1] SMZ Otto Wagner Spital, Inst Pathol & Bacteriol, A-1145 Vienna, Austria
[2] Biomech Forsch Gesell mbH, Vienna, Austria
[3] Univ Vienna, Dept Phys Chem, Vienna, Austria
[4] Orthopaed Hosp Gersthof, Vienna, Austria
关键词
Corrosion; Metal-induced hypersensitivity; Metal-on-metal; Hip replacement; IN-VIVO CORROSION; COBALT-CHROMIUM; WEAR; DEBRIS; PARTICLES; TITANIUM; RELEASE; IONS; ARTHROPLASTY; COMPONENTS;
D O I
10.1016/j.actbio.2008.07.032
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Aseptic loosening of articular implants is frequently associated with tissue reactions to wear particles. Some patients, who had received metal-on-metal articulations, present early symptoms including persistent pain and implant failure. These symptoms raise the suspicion about the development of an immunological response. Furthermore, the generation of rare corrosion products in association with metallic implants has been observed. Corrosion products are known to enhance third-body wear and contribute to the loss of the implant. The purpose of this study was to investigate periprosthetic tissue containing solid corrosion products after aseptic loosening of second-generation metal-on-metal total hip replacements made of low-carbon cobalt-chromium-molybdenum alloy for the presence of immunologically determined tissue changes. Periprosthetic tissue of 11 cases containing uncommon solid deposits was investigated by light microscopy. In order to confirm the presence of corrosion products, additional methods including scanning electron microscopy (SEM) investigation, energy dispersive X-ray (EDX) and Fourier transform infrared microspectroscopy (FTIR) analysis were used. All investigated cases revealed solid chromium orthophosphate corrosion products as well as metallic wear particles to a various extent. Moreover, various intense tissue reactions characteristic of immune response were observed in all cases. The simultaneous presence of corrosion products and hypersensitivity-associated tissue reaction indicates that a relationship between corrosion development and implant-related hypersensitivity may exist. (C) 2008 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:172 / 180
页数:9
相关论文
共 44 条
[1]
DOES CORROSION MATTER [J].
BLACK, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :517-520
[2]
WIDESPREAD DISSEMINATION OF METAL DEBRIS FROM IMPLANTS [J].
CASE, CP ;
LANGKAMER, VG ;
JAMES, C ;
PALMER, MR ;
KEMP, AJ ;
HEAP, PF ;
SOLOMON, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :701-712
[3]
Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty [J].
Clarke, MT ;
Lee, PTH ;
Arora, A ;
Villar, RN .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06) :913-917
[4]
CORROSION BETWEEN THE COMPONENTS OF MODULAR FEMORAL HIP PROSTHESES [J].
COLLIER, JP ;
SURPRENANT, VA ;
JENSEN, RE ;
MAYOR, MB ;
SURPRENANT, HP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (04) :511-517
[5]
CORROSION AND WEAR AT THE MODULAR INTERFACE OF UNCEMENTED FEMORAL STEMS [J].
COOK, SD ;
BARRACK, RL ;
CLEMOW, AJT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :68-72
[6]
An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements [J].
Davies, AP ;
Willert, HG ;
Campbell, PA ;
Learmonth, ID ;
Case, CP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :18-27
[7]
Metal-on-metal total hip replacement - What does the literature say? [J].
Dumbleton, JH ;
Manley, MT .
JOURNAL OF ARTHROPLASTY, 2005, 20 (02) :174-188
[8]
IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING [J].
GILBERT, JL ;
BUCKLEY, CA ;
JACOBS, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12) :1533-1544
[9]
Cytokine release in mononuclear cells of patients with Co-Cr hip prosthesis [J].
Granchi, D ;
Ciapetti, G ;
Stea, S ;
Savarino, L ;
Filippini, F ;
Sudanese, A ;
Zinghi, G ;
Montanaro, L .
BIOMATERIALS, 1999, 20 (12) :1079-1086
[10]
Metal sensitivity in patients with orthopaedic implants [J].
Hallab, N ;
Merritt, K ;
Jacobs, JJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (03) :428-436