Integration of physiological and accelerometer data to improve physical activity assessment

被引:88
作者
Strath, SJ
Brage, S
Ekelund, U
机构
[1] Univ Wisconsin, Dept Human Movement Sci, Milwaukee, WI 53201 USA
[2] Univ Cambridge, MRC, Epidemiol Unit, Inst Publ Hlth, Cambridge CB2 1TN, England
关键词
energy expenditure; HR; monitoring; exercise; behavior;
D O I
10.1249/01.mss.0000185650.68232.3f
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: Accurate measurement of physical activity (PA) is a prerequisite to determine dose-response relationships between activity and health. The combination of HR and accelerometers (ACC) holds promise for improving the accuracy of PA assessment, but it is unclear how currently proposed modeling techniques compare and to what extent different levels of individual calibration (IC) of HR influence monitoring accuracy. Methods: A total of 10 men and women (25.8 +/- 3.4 yr, 1.70 +/- 0.1 m, 71.7 +/- 11.8 kg, 24.4 +/- 5.0 kg(.)m(-2)) were recruited for this study, in which IC of HR to PA energy expenditure (PAEE) during both arm crank and treadmill activity were available. Participants completed 6 h of free-living activity, during which PAEE (obtained with indirect calorimetry), HR, hip ACC, arm ACC, and leg ACC were collected. PAEE was then modeled from two different methods of combining HR and ACC (arm-leg HR+M and branched model), both with IC and group-level calibration (GC) of HR, and also from hip ACC estimates alone. Estimates of PAEE were compared with criterion values for PAEE. Results: Combined estimates of PAEE from the arm-leg HR+M and the branched model were similar when IC was used (R-2 = 0.81, SEE = 0.55 METs and R-2 = 0.75, SEE = 0.61 METs, respectively). When using GC, all estimates of PAEE had larger error, but the performance of the branched model suffered less than the arm-leg HR+M model (R2 = 0.75, SEE = 0.67 METs and R-2 = 0.67, SEE = 0.88 METs, respectively). Both combination modeling techniques were more precise than single-measure hip ACC estimates (R-2 = 0.41, SEE = 0.96 METs). Conclusion: The combination of HR and ACC improves the accuracy of PAEE estimates and could be applied in large-scale epidemiological studies.
引用
收藏
页码:S563 / S571
页数:9
相关论文
共 35 条
[1]  
[Anonymous], 2002, Physical Activity Assessments for Health-Related Research
[2]  
AVONS P, 1988, EUR J CLIN NUTR, V42, P185
[3]   Validity and reliability issues in objective monitoring of physical activity [J].
Bassett, DR .
RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2000, 71 (02) :S30-S36
[4]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[7]   Reliability and validity of the combined heart rate and movement sensor Actiheart [J].
Brage, S ;
Brage, N ;
Franks, PW ;
Ekelund, U ;
Wareham, NJ .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2005, 59 (04) :561-570
[8]   Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure [J].
Brage, S ;
Brage, N ;
Franks, PW ;
Ekelund, U ;
Wong, MY ;
Andersen, LB ;
Froberg, K ;
Wareham, NJ .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (01) :343-351
[9]   The technology of accelerometry-based activity monitors: Current and future [J].
Chen, KY ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11) :S490-S500
[10]  
Ekelund U, 2005, AM J CLIN NUTR, V81, P964