Fiber optic ion-microsensors based on luminescence lifetime

被引:12
作者
Werner, T [1 ]
Klimant, I [1 ]
Huber, C [1 ]
Krause, C [1 ]
Wolfbeis, OS [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
关键词
microsensor; energy transfer; luminescence decay time; ion sensor;
D O I
10.1007/s006040050005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fiber optic ion-microsensors based on luminescence decay time have been developed for chloride and potassium. The fiber tip coatings consist of the respective ion-selective lipophilic ion carrier, plasticized PVC, and the ruthenium(II) tris-4,4'-diphenyl-2,2'-bipyridyl ion-pair with Bromothymol Blue [Ru(dibipy)(3)(BTB)(2)] as a proton donor. The efficacy of radiationless fluorescence energy transfer from the donor (the ruthenium complex) to the acceptor (BTB) is mediated by the ion concentration within the samples. The chloride response is based on the co-extraction of chloride along with protons from the aqueous sample into a plastiziced PVC membrane, whereas in the presence of potassium ions in the sample, the neutral BTB becomes deprotonated on extraction of potassium ions, with the release of protons. Both processes result in a change in BTB absorbance. The absorption band of deprotonated BTB overlaps significantly with the emission band of the ruthenium complex, allowing radiationless energy transfer to take place.
引用
收藏
页码:25 / 28
页数:4
相关论文
共 19 条
[11]   Dissolved oxygen sensor based on fluorescence quenching of oxygen-sensitive ruthenium complexes immobilized in sol-gel-derived porous silica coatings [J].
McEvoy, AK ;
McDonagh, CM ;
MacCraith, BD .
ANALYST, 1996, 121 (06) :785-788
[12]   New polar plasticizers for luminescence-based sensors [J].
Papkovsky, DB ;
Mohr, GJ ;
Wolfbeis, OS .
ANALYTICA CHIMICA ACTA, 1997, 337 (02) :201-205
[13]   PHOSPHORESCENT COMPLEXES OF PORPHYRIN KETONES - OPTICAL-PROPERTIES AND APPLICATION TO OXYGEN SENSING [J].
PAPKOVSKY, DB ;
PONOMAREV, GV ;
TRETTNAK, W ;
OLEARY, P .
ANALYTICAL CHEMISTRY, 1995, 67 (22) :4112-4117
[14]   Miniature sodium-selective ion-exchange optode with fluorescent pH chromoionophores and tunable dynamic range [J].
Shortreed, M ;
Bakker, E ;
Kopelman, R .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2656-2662
[15]   High-performance fiber optic pH microsensors for practical physiological measurements using a dual-emission sensitive dye [J].
Song, A ;
Parus, S ;
Kopelman, R .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :863-867
[16]   OPTICAL MEASUREMENTS OF PH USING FLUORESCENCE LIFETIMES AND PHASE-MODULATION FLUOROMETRY [J].
SZMACINSKI, H ;
LAKOWICZ, JR .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1668-1674
[17]   PHASE FLUOROMETRY USING A CONTINUOUSLY MODULATED LASER DIODE [J].
THOMPSON, RB ;
FRISOLI, JK ;
LAKOWICZ, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2075-2078
[18]   Set of luminescence decay time based chemical sensors for clinical applications [J].
Wolfbeis, OS ;
Klimant, I ;
Werner, T ;
Huber, C ;
Kosch, U ;
Krause, C ;
Neurauter, G ;
Dürkop, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :17-24
[19]  
0837327