Low-dose multidetector-row CT angiography of the infra-renal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSA

被引:105
作者
Fraioli, F [1 ]
Catalano, C [1 ]
Napoli, A [1 ]
Francone, M [1 ]
Venditti, F [1 ]
Danti, M [1 ]
Pediconi, F [1 ]
Passariello, R [1 ]
机构
[1] Univ Roma La Sapienza, Dept Radiol Sci, I-00161 Rome, Italy
关键词
computed tomography/angiography; digital subtraction angiography; radiation; arteries;
D O I
10.1007/s00330-005-2812-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
To investigate the possibility of reducing X-ray exposure during multidetector-row spiral computed tomographic (MDCT) angiography and to compare the image quality and diagnostic accuracy of different dosages with digital subtraction angiography (DSA) in the evaluation of the infra-renal aorta and lower extremities vessels. Seventy-five patients, randomly divided into three groups of 25 patients each, were evaluated for atherosclerotic disease with four-row spiral CT angiography (4x2.5 mm) and DSA. MDCT scanning parameters were kept constant, except for milliamperage (mAs): group A: 50 mAs; group B: 100 mAs; group C: 130 mAs. Images were analysed by two vascular radiologists in consensus. DSA represented the standard of reference. The diagnostic value of MDCT and total radiation exposure were evaluated for each data set. The simulated effective dose was 3.7 mSv for 50 mAs, 8.2 mSv for 100 mAs and 13.7 mSv for 130 mAs for men, and 4 mSv for 50 mAs, 8.9 mSv for 100 mAs and 14.8 mSv for 130 mAs for women. The dose reduction was 74% for group A and 40% for group B. The evaluation of the presence and degree of stenoses revealed a sensitivity, specificity, accuracy, PPV and NPV of 96%, 94%, 95%, 83% and 99% for Group A (50 mAs), 96%, 96%, 96%, 89% and 99% for Group B (100 mAs) and 98%, 96%, 97%, 91% and 100% for the standard dose protocol, Group C (130 mAs). Low-dose scanning is thus a feasible and accurate option for four-row CT angiography of the peripheral vessels. This technique provides substantial reduction of the radiation dose delivered to the patient while maintaining optimal diagnostic accuracy.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 29 条
[1]
[Anonymous], 1991, Annals of the ICRP, V21
[2]
Nephrotoxic effects in high-risk patients undergoing angiography. [J].
Aspelin, P ;
Aubry, P ;
Fransson, S ;
Strasser, R ;
Willenbrock, R ;
Berg, KJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (06) :491-499
[3]
Infrarenal aortic and lower-extremity arterial disease: Diagnostic performance of multi-detector row CT angiography [J].
Catalano, C ;
Fraioli, F ;
Laghi, A ;
Napoli, A ;
Bezzi, M ;
Pediconi, F ;
Danti, M ;
Nofroni, I ;
Passariello, R .
RADIOLOGY, 2004, 231 (02) :555-563
[4]
Radiation dose in helical CT for detection of pulmonary embolism [J].
Diederich, S .
EUROPEAN RADIOLOGY, 2003, 13 (07) :1491-1493
[6]
Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[7]
Detection of colorectal lesions: Lower-dose multi-detector row helical CT colonograph compared with conventional colonoscopy [J].
Iannaccone, R ;
Laghi, A ;
Catalano, C ;
Brink, JA ;
Mangiapane, F ;
Trenna, S ;
Piacentini, F ;
Passariello, R .
RADIOLOGY, 2003, 229 (03) :775-781
[8]
Calculation of computed tomography dose index to effective dose conversion factors based on measurement of the dose profile along the fan shaped beam [J].
Jansen, JTM ;
Geleijns, J ;
Zweers, D ;
Schultz, FW ;
Zoetelief, J .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (817) :33-41
[9]
A PC program for estimating organ dose and effective dose values in computed tomography [J].
Kalender, WA ;
Schmidt, B ;
Zankl, M ;
Schmidt, M .
EUROPEAN RADIOLOGY, 1999, 9 (03) :555-562
[10]
UPDATE ON SOME EPIDEMIOLOGIC FEATURES OF INTERMITTENT CLAUDICATION - THE FRAMINGHAM-STUDY [J].
KANNEL, WB ;
MCGEE, DL .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1985, 33 (01) :13-18