Analysis of surface dose variation in CT procedures

被引:20
作者
Lucas, PA
Castellano, IA
Dance, DR
Carruana, EV
机构
[1] Royal Marsden NHS Trust, Dept Phys, London SW3 6JJ, England
[2] Univ Complutense Madrid, Fac Med, Dept Radiol, E-28040 Madrid, Spain
关键词
D O I
10.1259/bjr.74.888.741128
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An experimental and theoretical study has been made of the variations in air kerma-length product (AKLP) at the surface of a phantom exposed in a CT scanner, using clinical parameters. For the theoretical part, a computer simulation was developed, based on a simple analytical model, requiring information generic to the scanner model. The effects of patient size, position within the gantry plane and beam-shaping filter type were studied using three different elliptical phantoms. A dose reduction technique based on a sinusoidal tube current modulation system was also investigated. The surface AKLP was shown to be independent of phantom size (within experimental error) but decreases as the surface moves vertically away from the isocentre. The major contributor to this variation is the beam-shaping filter. A maximum difference of 19% between the values of surface AKLP was calculated for the two beans-shaping filters available. When the tube current modulation system was used. the maximum surface dose reduction was 18%. A maximum difference of 2% was found between measurements and computer simulations. It is therefore possible to predict the behaviour of AKLP using the analytical model. As the dose measured on the surface of a patient is simply related to AKLP, the model can be applied to data obtained from patient surface dose surveys and can be helpful in interpreting the sources of variation in the latter.
引用
收藏
页码:1128 / 1136
页数:9
相关论文
共 20 条
[1]   A comparison of radiation dose measured in CT dosimetry phantoms with calculations using EGS4 and voxel-based computational models [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01) :219-229
[2]   Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies [J].
Gies, M ;
Kalender, WA ;
Wolf, H ;
Suess, C ;
Madsen, MT .
MEDICAL PHYSICS, 1999, 26 (11) :2235-2247
[3]   A simple theorem relating noise anti patient dose in computed tomography [J].
Harpen, MD .
MEDICAL PHYSICS, 1999, 26 (11) :2231-2234
[4]   Effective doses to patients undergoing thoracic computed tomography examinations [J].
Huda, W ;
Scalzetti, EM ;
Roskopf, M .
MEDICAL PHYSICS, 2000, 27 (05) :838-844
[5]   An approach for the estimation of effective radiation dose at CT in pediatric patients [J].
Huda, W ;
Atherton, JV ;
Ware, DE ;
Cumming, WA .
RADIOLOGY, 1997, 203 (02) :417-422
[6]   Calculation of computed tomography dose index to effective dose conversion factors based on measurement of the dose profile along the fan shaped beam [J].
Jansen, JTM ;
Geleijns, J ;
Zweers, D ;
Schultz, FW ;
Zoetelief, J .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (817) :33-41
[7]  
Jones D. G., 1993, NRPBSR250
[8]   Use of thyroid ultrasound volume in calculating radioactive iodine dose in hyperthyroidism [J].
Lucas, KJ .
THYROID, 2000, 10 (02) :151-155
[9]  
LUCAS PA, 1999, 12 C NAC FIS MED SES
[10]  
MENZEL HG, 1998, 16262 EUR EN EU