Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity

被引:159
作者
Saekho, S
Yip, CY
Noll, DC
Boada, FE
Stenger, VA
机构
[1] Univ Hawaii, Magnet Resonance Res Ctr, UH QMC, John A Burns Sch Med,Dept Med, Honolulu, HI 96813 USA
[2] Chiang Mai Univ, Fac Associated Med Sci, Chiang Mai 50000, Thailand
[3] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[5] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15260 USA
关键词
B-1; inhomogeneity; high magnetic fields; tailored RF pulses; human brain; MRI;
D O I
10.1002/mrm.20840
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article presents a small-flip-angle, three-dimensional tailored RF pulse that excites thin slices with an adjustable quadratic in-plane spatial variation. The quadratic spatial variation helps to compensate for the loss in image uniformity using a volume coil at 3 T due to the wavelike properties of the RF field. The pulse is based on a novel "fast-k(z)" design that uses a series of slice-select subpulses along k(z) and phase encoding "blips" along k(x)-k(y). The method is demonstrated by acquiring a series of 5-mm-thick T-2-weighted images of the human brain at 3 T using pulses 4.8 ms in length with a 45 degrees flip angle.
引用
收藏
页码:719 / 724
页数:6
相关论文
共 31 条
[1]   Radio frequency magnetic field mapping of a 3 tesla birdcage coil: Experimental and theoretical dependence on sample properties [J].
Alecci, M ;
Collins, CM ;
Smith, MB ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :379-385
[2]   Spiral volume coil for improved RF field homogeneity at high static magnetic field strength [J].
Alsop, DC ;
Connick, TJ ;
Mizsei, G .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (01) :49-54
[3]   RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING [J].
BOTTOMLEY, PA ;
ANDREW, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) :630-643
[4]  
Cohen MS, 2000, HUM BRAIN MAPP, V10, P204, DOI 10.1002/1097-0193(200008)10:4<204::AID-HBM60>3.0.CO
[5]  
2-2
[6]   SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil [J].
Collins, CM ;
Li, SZ ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :847-856
[7]   Central brightening due to constructive interference with, without, and despite dielectric resonance [J].
Collins, CM ;
Liu, WZ ;
Schreiber, W ;
Yang, QX ;
Smith, MB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :192-196
[8]   VARIABLE-RATE SELECTIVE EXCITATION [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A ;
GLOVER, G .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :440-458
[9]   Optimization of 3-D MP-RAGE sequences for structural brain imaging [J].
Deichmann, R ;
Good, CD ;
Josephs, O ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2000, 12 (01) :112-127
[10]   RF inhomogeneity compensation in structural brain imaging [J].
Deichmann, R ;
Good, CD ;
Turner, R .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :398-402