Linear viscoelastic behavior of subcutaneous adipose tissue

被引:197
作者
Geerligs, Marion [1 ,2 ]
Peters, Gerrit W. M. [3 ]
Ackermans, Paul A. J. [1 ]
Oomens, Cees W. J. [2 ]
Baaijens, Frank P. T. [2 ]
机构
[1] Philips Res, Care & Hlth Applicat, NL-5656 AE Eindhoven, Netherlands
[2] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[3] Eindhoven Univ Technol, Dept Mech Engn, NL-5600 MB Eindhoven, Netherlands
关键词
Mechanical properties; rheometry; hypodermis; time-temperature superposition; power-law model; snap freezing;
D O I
10.3233/BIR-2008-0517
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Subcutaneous adipose tissue contributes to the overall mechanical behavior of the skin. Until today, however, no thorough constitutive model is available for this layer of tissue. As a start to the development of such a model, the objective of this study was to measure and describe the linear viscoelastic behavior of subcutaneous adipose tissue. Although large strains occur in vivo, this work only focuses on the linear behavior to show the applicability of the described methods to adipose tissue. Shear experiments are performed on porcine samples on a rotational rheometer using parallel plate geometry. In the linear viscoelastic regime, up to 0.1% strain, the storage and loss modulus showed a frequency- and temperature-dependent behavior. The ratio between the two moduli, the phase angle, did not show any dependency on temperature and frequency. The shear modulus was found to be 7.5 kPa at 10 rad/s and 37 degrees C. Time-temperature superposition was applicable through shifting the shear modulus horizontally. A power-law function model was introduced to describe both the frequency dependent behavior at constant temperature and the stress relaxation behavior. In addition, the effect of snap freezing as a preservation method was analyzed. Histological examination demonstrated possible tissue damage after freezing, but the mechanical properties did not change. Since results were reproducible, it is concluded that the methods we used are most probably suited to explore the non-linear behavior of subcutaneous adipose tissue.
引用
收藏
页码:677 / 688
页数:12
相关论文
共 24 条
[1]
Subcutaneous fat in normal and diseased states - 2. Anatomy and physiology of white and brown adipose tissue [J].
Avram, AS ;
Avram, MM ;
James, WD .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2005, 53 (04) :671-683
[2]
[3]
A 9-mo randomized clinical trial comparing fat-substituted and fat-reduced diets in healthy obese men: the Ole Study [J].
Bray, GA ;
Lovejoy, JC ;
Most-Windhauser, M ;
Smith, SR ;
Volaufova, J ;
Denkins, Y ;
de Jonge, L ;
Rood, J ;
Lefevre, M ;
Eldridge, AL ;
Peters, JC .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2002, 76 (05) :928-934
[4]
An in vivo method for measuring the mechanical properties of the skin using ultrasound [J].
Diridollou, S ;
Berson, M ;
Vabre, V ;
Black, D ;
Karlsson, B ;
Auriol, F ;
Gregoire, JM ;
Yvon, C ;
Vaillant, L ;
Gall, Y ;
Patat, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (02) :215-224
[5]
FOUTZ TL, 1992, AM J VET RES, V53, P788
[6]
Viscoelastic properties of ovine adipose tissue covering the gluteus muscles [J].
Gefen, Amit ;
Haberman, Einat .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (06) :924-930
[7]
Assessment of elastic parameters of human skin using dynamic elastography [J].
Gennisson, JL ;
Baldeweck, T ;
Tanter, M ;
Catheline, S ;
Fink, M ;
Sandrin, L ;
Cornillon, C ;
Querleux, B .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (08) :980-989
[8]
A numerical-experimental method to characterize the non-linear mechanical behaviour of human skin [J].
Hendriks, FM ;
Brokken, D ;
van Eemeren, JTWM ;
Oomens, CWJ ;
Baaijens, FPT ;
Horsten, JBAM .
SKIN RESEARCH AND TECHNOLOGY, 2003, 9 (03) :274-283
[9]
The relative contributions of different skin layers to the mechanical behavior of human skin in vivo using suction experiments [J].
Hendriks, FM ;
Brokken, D ;
Oomens, CWJ ;
Bader, DL ;
Baaijens, FPT .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (03) :259-266
[10]
Subcutaneous tissue mechanical behavior is linear and viscoelastic under uniaxial tension [J].
Iatridis, JC ;
Wu, JR ;
Yandow, JA ;
Langevin, HM .
CONNECTIVE TISSUE RESEARCH, 2003, 44 (05) :208-217