Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta

被引:80
作者
May-Newman, K
Hillen, B
Dembitsky, W
机构
[1] San Diego State Univ, Dept Mech Engn, San Diego, CA 92182 USA
[2] Sharp Mem Hosp & Rehabil Ctr, Mech Assist Device Program, San Diego, CA USA
关键词
D O I
10.1097/01.mat.0000201961.97981.e9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computational fluid dynamics (CFD) models were developed to investigate the altered fluid dynamics of the native aorta in patients with a left ventricular assist device (LVAD). The objective of this study was to simulate the effect of LVAD aortic outflow conduit location on the 3-D flow in the native aorta over a range of boundary conditions. The fluid mechanics of three different surgical geometries [(P), proximal, (D), distal and (IP), in-plane] were studied and the implications for short- and long-term medical consequences explored by evaluating the flow fields, wall shear, and hemolysis. The greatest disruptions in the normal aortic flow pattern occurred with series flow conditions, when flow through the aortic valve was minimal. Under series conditions, circulation in the proximal aorta is retrograde, originating from the LVAD outflow conduit. The (P) geometry provided the most blood washout of the proximal aorta, with a larger region of slow-moving flow observed in the (D) and (IP) models. Wall shear stress was reduced for the (IP) geometry, which lacks the direct flow impingement present in the (P) and (D) models. Clinically, the (D) and (IP) geometries require less traumatic surgeries and probably are better tolerated by the patient. In this situation, the (IP) geometry suggests improvement in both increased flow to the proximal aorta and decreased shear stress compared with (D). However, the (D) and (IP) configurations are not recommended for patients with low or no flow from the heart because of the lack of blood washout near the aortic valve and therefore possible thrombus formation in that area.
引用
收藏
页码:132 / 139
页数:8
相关论文
共 44 条
[1]   SHEAR-STRESS AT A COMPLIANT MODEL OF THE HUMAN CAROTID BIFURCATION [J].
ANAYIOTOS, AS ;
JONES, SA ;
GIDDENS, DP ;
GLAGOV, S ;
ZARINS, CK .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (01) :98-106
[2]   Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics [J].
Apel, J ;
Paul, R ;
Klaus, S ;
Siess, T ;
Reul, H .
ARTIFICIAL ORGANS, 2001, 25 (05) :341-347
[3]   A new in vitro model to evaluate differential responses of endothelial cells to simulated arterial shear stress waveforms [J].
Blackman, BR ;
García-Cardeña, G ;
Gimbrone, MA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (04) :397-407
[4]   Steady flow in an aneurysm model: Correlation between fluid dynamics and blood platelet deposition [J].
Bluestein, D ;
Niu, L ;
Schoephoerster, RT ;
Dewanjee, MK .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :280-286
[5]   Visualizing blood flow patterns using streamlines, arrows, and particle paths [J].
Buonocore, MH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) :210-226
[6]   Computational fluid dynamics as a development tool for rotary blood pumps [J].
Burgreen, GW ;
Antaki, JF ;
Wu, ZJ ;
Holmes, AJ .
ARTIFICIAL ORGANS, 2001, 25 (05) :336-340
[7]   The HeartMate II: Design and development of a fully sealed axial flow left ventricular assist system [J].
Burke, DJ ;
Burke, E ;
Parsaie, F ;
Poirier, V ;
Butler, K ;
Thomas, D ;
Taylor, L ;
Maher, T .
ARTIFICIAL ORGANS, 2001, 25 (05) :380-385
[8]   Numerical calculation of hemolysis levels in peripheral hemodialysis cannulas [J].
De Wachter, D ;
Verdonck, P .
ARTIFICIAL ORGANS, 2002, 26 (07) :576-582
[9]   Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm [J].
Di Martino, ES ;
Guadagni, G ;
Fumero, A ;
Ballerini, G ;
Spirito, R ;
Biglioli, P ;
Redaelli, A .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (09) :647-655
[10]   Toward designing the optimal total cavopulmonary connection: An in vitro study [J].
Ensley, AE ;
Lynch, P ;
Chatzimavroudis, GP ;
Lucas, C ;
Sharma, S ;
Yoganathan, AP .
ANNALS OF THORACIC SURGERY, 1999, 68 (04) :1384-1390