Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue

被引:116
作者
Suprun, E
Evtugyn, G
Budnikov, H
Ricci, F
Moscone, D
Palleschi, G
机构
[1] Kazan VI Lenin State Univ, Dept Chem, Kazan 420008, Russia
[2] Univ Roma Tor Vergata, Dipartimento Sci & Technol Chim, I-00133 Rome, Italy
关键词
cholinesterase sensor; biosensor; pesticide detection; Prussian blue; wine contamination;
D O I
10.1007/s00216-005-0002-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Acetylcholinesterase (ChE) sensor based on Prussian blue (PB) modified electrode was developed and tested for the detection of organophosphorus and carbamic pesticides. The signal of the sensor was generated in PB mediated oxidation of thiocholine recorded at +200 mv in DC mode. ChE from electric eel was immobilized by cross-linking with glutaraldehyde in the presence of bovine senun albumin (BSA) on the surface of screen-printed carbon electrode covered with PB and Nafion. The content of the surface layer (specific enzyme activity, Nafion and BSA amounts) was optimized to establish high and reliable response toward the substrate and ChE inhibitors. The ChE/PB sensor makes it possible to detect Aldicarb, Paraoxon and Parathion-Methyl with limits of detection 30, 10 and 5 ppb, respectively (incubation 10 min). The feasibility of practical application of the ChE/PB sensor developed for the monitoring of degradation of the pesticides in wine fermentation was shown. To diminish matrix interferences, the electrolysis of the grape juice with Al anode and evaporation of ethanol were suggested, however the procedures decrease the sensitivity of pesticide detection and stability of the sample tested.
引用
收藏
页码:597 / 604
页数:8
相关论文
共 45 条
[21]  
JaffrezicRenault N, 1996, SENSOR MATER, V8, P161
[22]  
Jagriti Sharma, 2005, Chemical Health and Safety, V12, P17, DOI 10.1016/j.chs.2004.08.003
[23]   Detection of paraoxon by continuous flow system based enzyme sensor [J].
Jeanty, G ;
Marty, JL .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (02) :213-218
[24]   Prussian Blue-based 'artificial peroxidase' as a transducer for hydrogen peroxide detection. Application to biosensors [J].
Karyakin, AA ;
Karyakina, EE .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 57 (1-3) :268-273
[25]   CHARACTERIZATION AND STABILIZATION OF ENZYME BIOSENSORS [J].
KATAKIS, I ;
DOMINGUEZ, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) :310-319
[26]  
Lu W, 1998, ELECTROANAL, V10, P472, DOI 10.1002/(SICI)1521-4109(199806)10:7<472::AID-ELAN472>3.0.CO
[27]  
2-B
[28]   Glucose and choline on-line biosensors based on electropolymerized Meldola's blue [J].
Mao, LQ ;
Yamamoto, K .
TALANTA, 2000, 51 (01) :187-195
[29]   Determination of organophosphorus and carbamate pesticides using a biosensor based on a polishable, 7,7,8,8-tetracyanoquinodimethane-modified, graphite-epoxy biocomposite [J].
Martorell, D ;
Cespedes, F ;
MartinezFabregas, E ;
Alegret, S .
ANALYTICA CHIMICA ACTA, 1997, 337 (03) :305-313
[30]   Ferrocene-conjugated m-phenylenediamine conducting polymer-incorporated peroxidase biosensors [J].
Mulchandani, A ;
Pan, ST .
ANALYTICAL BIOCHEMISTRY, 1999, 267 (01) :141-147