Electronic tongue for the determination of alkaline ions using a screen-printed potentiometric sensor array

被引:24
作者
Gutierrez, Manuel [1 ]
Moo, Victor M. [2 ]
Alegret, Salvador [1 ]
Leija, Lorenzo [2 ]
Hernandez, Pablo R. [2 ]
Munoz, Roberto [2 ]
del Valle, Manel [1 ]
机构
[1] Univ Autonoma Barcelona, Sensors & Biosensors Grp, Dept Chem, E-08193 Barcelona, Spain
[2] CINVESTAV, Dept Elect Engn, Mexico City 14000, DF, Mexico
关键词
electronic tongue; screen-printing technique; sensor array; potentiometric sensors; artificial neural networks;
D O I
10.1007/s00604-007-0894-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable all-solid-state planar-type potentiometric electronic tongue has been developed with a five-sensor array screen-printed on a polymeric substrate. The fabrication method enables simple and reproducible mass-production of low-cost electronic tongue systems, since the sensors showed good reproducibility (0.96% RSD), repeatability (0.58% RSD) and lifetime (8% decrease of sensitivity after 37 days in solution). The system was used for the simultaneous determination of NH(4)(+), K(+) and Na(+) ions in synthetic and natural surface water samples. The signals were processed by using a multilayer artificial neural network which was optimized for that purpose. Correct results were obtained for the three ions in synthetic samples. In natural surface waters, ammonium and potassium ions could be determined, while sodium ions showed biased results due to the effect of the complex matrix.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 31 条
[21]  
MANEZ MR, 2005, SENSOR ACTUAT B-CHEM, V104, P302
[22]   Multi-sensor array used as an "electronic tongue" for mineral water analysis [J].
Moreno, L. ;
Merlos, A. ;
Abramova, N. ;
Jimenez, C. ;
Bratov, A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 116 (1-2) :130-134
[23]   A flow injection system based on chalcogenide glass sensors for the determination of heavy metals [J].
Mortensen, J ;
Legin, A ;
Ipatov, A ;
Rudnitskaya, A ;
Vlasov, Y ;
Hjuler, K .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :273-277
[24]   Data analysis for electronic nose systems [J].
Scott, Simon M. ;
James, David ;
Ali, Zulfiqur .
MICROCHIMICA ACTA, 2006, 156 (3-4) :183-207
[25]   The application of a chemical sensor array detector in ion chromatography for the determination of Na+, NH4+, K+, Mg2+ and Ca2+ in water samples [J].
Shen, HD ;
Cardwell, TJ ;
Cattrall, RW .
ANALYST, 1998, 123 (10) :2181-2184
[26]  
Skapura D.M., 1991, NEURAL NETWORKS ALGO
[27]   ION-SELECTIVE ELECTRODES BASED ON NATURAL CARBOXYLIC POLYETHER ANTIBIOTICS [J].
SUZUKI, K ;
TOHDA, K ;
ARUGA, H ;
MATSUZOE, M ;
INOUE, H ;
SHIRAI, T .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1714-1721
[28]   COATED WIRE SODIUM-SELECTIVE AND POTASSIUM-SELECTIVE ELECTRODES BASED ON BIS(CROWN ETHER) COMPOUNDS [J].
TAMURA, H ;
KIMURA, K ;
SHONO, T .
ANALYTICAL CHEMISTRY, 1982, 54 (07) :1224-1227
[29]   Taste sensor [J].
Toko, K .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 64 (1-3) :205-215
[30]  
Umezawa Y., 1990, HDB ION SELECTIVE EL