Navigation knee replacement

被引:23
作者
Dattani, Rupen [1 ]
Patnaik, Surendra [1 ]
Kantak, Avadhoot [1 ]
Tselentakis, Georgis [1 ]
机构
[1] E Surrey Hosp, Dept Orthopaed Surg, Redhill RH1 5RH, Surrey, England
关键词
ARTHROPLASTY; ALIGNMENT; SURGERY; HIP; EXPERIENCE; LIFE;
D O I
10.1007/s00264-008-0671-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Total knee replacement (TKR) achieves an immediate and exceptional restoration in the quality of life that is comparable only to a few other procedures. It has been suggested that the most common cause of revision TKR is error in surgical technique, from malpositioning of the components which results in a poorer post-operative outcome. Based on the theoretical assumption that the use of computer-assisted systems (CAS) in TKRs may improve implant alignment and thus implant longevity, the use of this technology is becoming increasingly popular. This article (a) reviews whether computer-assisted TKR (CASTKR) results in improved prosthesis alignment compared with the conventional technique, (b) assesses the functional and clinical outcomes of CASTKR and (c) evaluates the cost-effectiveness of using this technology.
引用
收藏
页码:7 / 10
页数:4
相关论文
共 45 条
[1]
Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Perlick, C ;
Grifka, J .
INTERNATIONAL ORTHOPAEDICS, 2004, 28 (02) :87-90
[2]
Navigated total knee replacement - A meta-analysis [J].
Bauwens, Kai ;
Matthes, Gerrit ;
Wich, Michael ;
Gebhard, Florian ;
Hanson, Beate ;
Ekkernkamp, Axel ;
Stengel, Dirk .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) :261-269
[3]
Experiences with computer navigated total knee arthroplasty [J].
Bejek, Zoltan ;
Solyom, Laszlo ;
Szendroi, Miklos .
INTERNATIONAL ORTHOPAEDICS, 2007, 31 (05) :617-622
[4]
An analysis of blood management in patients having a total hip or knee arthroplasty [J].
Bierbaum, BE ;
Callaghan, JJ ;
Galante, JO ;
Rubash, HE ;
Tooms, RE ;
Welch, RB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :2-10
[5]
Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[6]
The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty [J].
Chiu, K. Y. ;
Yau, W. P. ;
Ng, T. P. ;
Tang, W. M. .
INTERNATIONAL ORTHOPAEDICS, 2008, 32 (04) :467-471
[7]
Embolic phenomena during computer-assisted and conventional total knee replacement [J].
Church, J. S. ;
Scadden, J. E. ;
Gupta, R. R. ;
Cokis, C. ;
Williams, K. A. ;
Janes, G. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04) :481-485
[8]
Early assessment of the likely cost-effectiveness of a new technology: A Markov model with probabilistic sensitivity analysis of computer-assisted total knee replacement [J].
Dong, HJ ;
Buxton, M .
INTERNATIONAL JOURNAL OF TECHNOLOGY ASSESSMENT IN HEALTH CARE, 2006, 22 (02) :191-202
[9]
Total knee arthroplasty implanted with and without kinematic navigation [J].
Hart, R ;
Janecek, M ;
Chaker, A ;
Bucek, P .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (06) :366-369
[10]
Health-related quality of life after knee replacement - Results of the Knee Replacement Patient Outcomes Research Team Study [J].
Hawker, G ;
Wright, J ;
Coyte, P ;
Paul, J ;
Dittus, R ;
Croxford, R ;
Katz, B ;
Bombardier, C ;
Heck, D ;
Freund, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (02) :163-173