Rapid detection of foodborne contaminants using an Array Biosensor

被引:70
作者
Sapsford, KE
Ngundi, MM
Moore, MH
Lassman, ME
Shriver-Lake, LC
Taitt, CR
Ligler, FS [2 ]
机构
[1] George Mason Univ, Manassas, VA 20110 USA
[2] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
关键词
Array Biosensor; sandwich immunoassay; competitive immunoassay; bacteria; Campylobacter jejuni; mycotoxins; multi-analyte;
D O I
10.1016/j.snb.2005.07.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Foodborne contaminants come in a variety of sizes ranging from simple chemical compounds to entire bacterial cells. Due to public health concerns, there is a current need in the food industry for a sensitive, specific and rapid method to monitor for the presence of these toxic species, either as a result of natural or deliberate contamination. The Array Biosensor developed at the NRL encompasses these qualities, including the ability to measure multiple analytes simultaneously on a single substrate. In this study, we demonstrate the Array Biosensor's ability to measure both large pathogens, such as the bacteria Campylobacter jejuni (C. jejuni), and small toxins, including the mycotoxins ochratoxin A, fumonisin B, aflatoxin B-1 and deoxynivalenol. Sandwich immunoassays were used to measure C. jejuni in buffer and a number of food matrices, while competitive immunoassays, taking only 15 min, were developed for the simultaneous detection of multiple mycotoxins. The combination of sandwich and competitive immunoassay formats on a single substrate was demonstrated, allowing the simultaneous detection of both large (C. jejuni) and small (aflatoxin B 1) food contaminants. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 19 条
[1]   Market analysis of biosensors for food safety [J].
Alocilja, EC ;
Radke, SM .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :841-846
[2]  
[Anonymous], 2003, 139 CAST
[3]   Array Biosensor: Optical and Fluidics Systems [J].
Feldstein, Mark J. ;
Golden, Joel P. ;
Rowe, Chris A. ;
MacCraith, Brian D. ;
Ligler, Frances S. .
BIOMEDICAL MICRODEVICES, 1999, 1 (02) :139-153
[4]   Mycotoxins as harmful indoor air contaminants [J].
Jarvis, BB ;
Miller, JD .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2005, 66 (04) :367-372
[5]   Infective dose of foodborne pathogens in volunteers: A review [J].
Kothary, MH ;
Babu, US .
JOURNAL OF FOOD SAFETY, 2001, 21 (01) :49-73
[6]   Foodborne enteric infections [J].
Mao, Y ;
Zhu, CG ;
Boedeker, EC .
CURRENT OPINION IN GASTROENTEROLOGY, 2003, 19 (01) :11-22
[7]   Array biosensor for detection of ochratoxin A in cereals and beverages [J].
Ngundi, MM ;
Shriver-Lake, LC ;
Moore, MH ;
Lassman, ME ;
Ligler, FS ;
Taitt, CR .
ANALYTICAL CHEMISTRY, 2005, 77 (01) :148-154
[8]   Array biosensor for simultaneous identification of bacterial, viral, and protein analytes [J].
Rowe, CA ;
Tender, LM ;
Feldstein, MJ ;
Golden, JP ;
Scruggs, SB ;
MacCraith, BD ;
Cras, JJ ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3846-3852
[9]   An array immunosensor for simultaneous detection of clinical analytes [J].
Rowe, CA ;
Scruggs, SB ;
Feldstein, MJ ;
Golden, JP ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :433-439
[10]   Array biosensor for detection of biohazards [J].
Rowe-Taitt, CA ;
Golden, JP ;
Feldstein, MJ ;
Cras, JJ ;
Hoffman, KE ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :785-794