摘要
Efforts to develop metallic zinc for biodegradable implants have significantly advanced following an earlier focus on magnesium (Mg) and iron (Fe). Mg and Fe base alloys experience an accelerated corrosion rate and harmful corrosion products, respectively. The corrosion rate of pure Zn, however, may need to be modified from its reported similar to 20 mu m/year penetration rate, depending upon the intended application. The present study aimed at evaluating the possibility of using Fe as a relatively cathodic biocompatible alloying element in zinc that can tune the implant degradation rate via microgalvanic effects. The selected Zn-1.3wt % Fe alloy composition produced by gravity casting was examined in vitro and in vivo. The in vitro examination included immersion tests, potentiodynamic polarization and impedance spectroscopy, all in a simulated physiological environment (phosphate-buffered saline, PBS) at 37 degrees C. For the in vivo study, two cylindrical disks (seven millimeters diameter and two millimeters height) were implanted into the back midline of male Wister rats. The rats were examined post implantation in terms of weight gain and hematological characteristics, including red blood cell (RBC), hemoglobin (HGB) and white blood cell (WBC) levels. Following retrieval, specimens were examined for corrosion rate measurements and histological analysis of subcutaneous tissue in the implant vicinity. In vivo analysis demonstrated that the Zn-1.3% Fe implant avoided harmful systemic effects. The in vivo and in vitro results indicate that the Zn-1.3% Fe alloy corrosion rate is significantly increased compared to pure zinc. The relatively increased degradation of Zn-1.3% Fe was mainly related to microgalvanic effects produced by a secondary Zn11Fe phase.
引用
收藏
页数:15
相关论文
共 60 条
[1]
The effect of Ca on the in vitro corrosion performance of biodegradable Mg-Nd-Y-Zr alloy [J].
Aghion, E. ;
Levy, G. .
JOURNAL OF MATERIALS SCIENCE, 2010, 45 (11) :3096-3101
[2]
Al-Maroof RA, 2006, SAUDI MED J, V27, P344
[3]
Characterization of nanostructured biodegradable Zn-Mn alloy synthesized by mechanical alloying [J].
Bagha, P. Sotoudeh ;
Khaleghpanah, S. ;
Sheibani, S. ;
Khakbiz, M. ;
Zakeri, A. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 735 :1319-1327
[4]
Fabrication of biodegradable Zn-Al-Mg alloy: Mechanical properties, corrosion behavior, cytotoxicity and antibacterial activities [J].
Bakhsheshi-Rad, H. R. ;
Hamzah, E. ;
Low, H. T. ;
Kasiri-Asgarani, M. ;
Farahany, S. ;
Akbari, E. ;
Cho, M. H. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 73 :215-219
[5]
Evaluation of wrought Zn-Al alloys (1, 3, and 5 wt % Al) through mechanical and in vivo testing for stent applications [J].
Bowen, Patrick K. ;
Seitz, Jan-Marten ;
Guillory, Roger J., II ;
Braykovich, Jacob P. ;
Zhao, Shan ;
Goldman, Jeremy ;
Drelich, Jaroslaw W. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (01) :245-258
[6]
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys [J].
Bowen, Patrick K. ;
Shearier, Emily R. ;
Zhao, Shan ;
Guillory, Roger J., II ;
Zhao, Feng ;
Goldman, Jeremy ;
Drelich, Jaroslaw W. .
ADVANCED HEALTHCARE MATERIALS, 2016, 5 (10) :1121-1140
[7]
Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents [J].
Bowen, Patrick K. ;
Guillory, Roger J., II ;
Shearier, Emily R. ;
Seitz, Jan-Marten ;
Drelich, Jaroslaw ;
Bocks, Martin ;
Zhao, Feng ;
Goldman, Jeremy .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 56 :467-472
[8]
New approaches in evaluating metallic candidates for bioabsorbable stents [J].
Bowen, Patrick K. ;
Drelich, Jaroslaw ;
Buxbaum, Robert E. ;
Rajachar, Rupak M. ;
Goldman, Jeremy .
EMERGING MATERIALS RESEARCH, 2012, 1 (05) :237-255
[9]
Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents [J].
Bowen, Patrick K. ;
Drelich, Jaroslaw ;
Goldman, Jeremy .
ADVANCED MATERIALS, 2013, 25 (18) :2577-2582
[10]
Biocompatibility of magnesium-zinc alloy in biodegradable orthopedic implants [J].
Chen, Daoyun ;
He, Yaohua ;
Tao, Hairong ;
Zhang, Yan ;
Jiang, Yao ;
Zhang, Xiaonong ;
Zhang, Shaoxiang .
INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 2011, 28 (03) :343-348