Shuttle dose at the Vienna Leksell Gamma Knife

被引:24
作者
Ertl, A [1 ]
Zehetmayer, M
Schoggl, A
Kitz, K
Koschuch, R
Stadtmann, H
Kindl, P
机构
[1] Univ Vienna, Dept Neurosurg, Wahringer Gurtel 18-20, A-1090 Vienna, Austria
[2] Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
[3] Graz Univ, Inst Tech Phys, A-8010 Graz, Austria
[4] Osterreich Forschungszentrum Seibersdorf GmbH, A-2444 Seibersdorf, Austria
关键词
D O I
10.1088/0031-9155/43/6/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to determine the shuttle dose for all collimator helmets (4, 8, 14 and 18 mm) of the Gamma Knife, model B, in Vienna, Austria. The additional dose accumulated during the transport of the patient in and out of the treatment position should be considered in the dose planning procedure of multicentre treatment regimens and in fractionated stereotactic Gamma Knife radiotherapy. The GafChromic film study was basically used to determine the shuttle dose of all four collimator helmets. In addition, measurements with an ionization chamber (18 and 14 mm collimator) - and, for the 18 mm collimator helmet, TLD dosimetry - were performed in order to confirm the GafChromic film data. The shuttle dose ranged between 99.6 and 183.5 mGy, depending mainly on the size of the collimator and the irradiated isocentres at the half-life activity of Co-60 in a brand new Gamma unit. Our film-generated data were in good correlation with the dose levels obtained with the ionization chamber and the TLD dosimetry, showing a dose difference of less than 0.8%. Since it was possible to verify the shuttle dose even for the 4 and 8 mm collimator helmets, we consider it a non-negligible factor and would advocate the inclusion of the shuttle dose in radiosurgical dose planning.
引用
收藏
页码:1567 / 1578
页数:12
相关论文
共 16 条
[1]  
CHU RDH, 1990, RADIAT PHYS CHEM, V35, P767
[2]   Precision dosimetry in narrow collimated radiation beams of the Leksell Gamma Knife [J].
Duftschmid, KE ;
Kind, P ;
Obenaus, B ;
Strachotinsky, C ;
Winker, N .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :295-298
[3]   Dosimetry studies with TLDs for stereotactic radiation techniques for intraocular tumours [J].
Ertl, A ;
Zehetmayer, M ;
Schoggl, A ;
Kindl, P ;
Hartl, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2137-2145
[4]   TLD array for precise dose measurements in stereotactic radiation techniques [J].
Ertl, A ;
Hartl, RFE ;
Zehetmayer, M ;
Kitz, K ;
Griffitt, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2679-2686
[5]   GafChromic MD-55: Investigated as a precision dosimeter [J].
Klassen, NV ;
van der Zwan, L ;
Cygler, J .
MEDICAL PHYSICS, 1997, 24 (12) :1924-1934
[6]   THE USE OF A RADIOCHROMIC DETECTOR FOR THE DETERMINATION OF STEREOTAXIC RADIOSURGERY DOSE CHARACTERISTICS [J].
MCLAUGHLIN, WL ;
SOARES, CG ;
SAYEG, JA ;
MCCULLOUGH, EC ;
KLINE, RW ;
WU, A ;
MAITZ, AH .
MEDICAL PHYSICS, 1994, 21 (03) :379-388
[7]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176
[8]   Dosimetric characteristics of an improved radiochromic film [J].
Meigooni, AS ;
Sanders, MF ;
Ibbott, GS ;
Szeglin, SR .
MEDICAL PHYSICS, 1996, 23 (11) :1883-1888
[9]  
MEIGOONI AS, 1993, MED PHYS, V20, P1298
[10]   PHOTON ENERGY-DEPENDENCE OF THE SENSITIVITY OF RADIOCHROMIC FILM AND COMPARISON WITH SILVER-HALIDE FILM AND LIF TLDS USED FOR BRACHYTHERAPY DOSIMETRY [J].
MUENCH, PJ ;
MEIGOONI, AS ;
NATH, R ;
MCLAUGHLIN, WL .
MEDICAL PHYSICS, 1991, 18 (04) :769-775