Electrostatic force sensitive scanning probe microscopy is used to quantify dc and ac transport properties of an active Schottky barrier diode. Scanning surface potential microscopy (SSPM) of the laterally biased device is used to quantify the potential drop at the metal-semiconductor interface. Ramping the lateral bias allows the local voltage and I-V characteristics of the diode to be reconstructed. Scanning impedance microscopy (SIM) demonstrates the phase and amplitude change of voltage oscillations across the interface. The frequency dependence of voltage phase shifts across the interface defines the appropriate equivalent circuit for the reverse biased junction. Excellent agreement between junction capacitance obtained from SIM measurements and impedance spectroscopy is demonstrated. Variation of the dc component of lateral bias in SIM yields the local capacitance-voltage characteristics of the junction. SIM contrast of grain boundaries in p-doped silicon was interpreted in terms of minority carrier generation in the interface region. The combination of SSPM and SIM provides an approach for the quantitative analysis of local dc and ac transport properties which were demonstrated for a Schottky diode but can be applied to any semiconductor device. (C) 2002 American Institute of Physics.
引用
收藏
页码:832 / 839
页数:8
相关论文
共 30 条
[11]   Surface potential at surface-interface junctions in SrTiO3 bicrystals [J].
Kalinin, SV ;
Bonnell, DA .
PHYSICAL REVIEW B, 2000, 62 (15) :10419-10430
[12]   Local potential and polarization screening on ferroelectric surfaces [J].
Kalinin, SV ;
Bonnell, DA .
PHYSICAL REVIEW B, 2001, 63 (12)
[13]   Scanning impedance microscopy of electroactive interfaces [J].
Kalinin, SV ;
Bonnell, DA .
APPLIED PHYSICS LETTERS, 2001, 78 (09) :1306-1308
[14]  
KALININ SV, UNPUB
[15]   Scanning capacitance microscopy imaging of silicon metal-oxide-semiconductor field effect transistors [J].
Kleiman, RN ;
O'Malley, ML ;
Baumann, FH ;
Garno, JP ;
Timp, GL .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2000, 18 (04) :2034-2038
[16]   Observation of metal-oxide-semiconductor transistor operation using scanning capacitance microscopy [J].
Nakakura, CY ;
Hetherington, DL ;
Shaneyfelt, MR ;
Shea, PJ ;
Erickson, AN .
APPLIED PHYSICS LETTERS, 1999, 75 (15) :2319-2321
[17]   Cross-sectional imaging of semiconductor device structures by scanning resistance microscopy [J].
Nxumalo, JN ;
Shimizu, DT ;
Thomson, DJ .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (01) :386-389
[18]   Quantification of scanning capacitance microscopy imaging of the pn junction through electrical simulation [J].
O'Malley, ML ;
Timp, GL ;
Moccio, SV ;
Garno, JP ;
Kleiman, RN .
APPLIED PHYSICS LETTERS, 1999, 74 (02) :272-274
[19]  
Sarid D., 1991, SCANNING FORCE MICRO
[20]   Detection of doping atom distributions and individual dopants in InAs(110) by dynamic-mode scanning force microscopy in ultrahigh vacuum [J].
Schwarz, A ;
Allers, W ;
Schwarz, UD ;
Wiesendanger, R .
PHYSICAL REVIEW B, 2000, 62 (20) :13617-13622