Contrast-enhanced magnetic resonance angiography of the renal arteries - Original investigation

被引:41
作者
Hany, TF [1 ]
Leung, DA [1 ]
Pfammatter, T [1 ]
Debatin, JF [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
关键词
renovascular hypertension; renal insufficiency; catheter angiography; contrast-enhanced 3D magnetic resonance; angiography;
D O I
10.1097/00004424-199809000-00021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors determine the value of contrast-enhanced, three-dimensional (3D) magnetic resonance angiography (MRA) in the assessment of the renal arteries in comparison with conventional arteriography (CA), METHODS. One hundred three patients (71 m, 32 f) were evaluated with both CA and 3D MRA, The 3D MRA data set consisted of 44 contiguous sections, acquired in apnea (23-28 seconds) using the following parameters: TR/TE 3.9/1.5 milliseconds, flip angle 40 degrees to 50 degrees, 3/4 k-space acquisition. A bolus of 0.3 mmol/kg BW gadolinium-DTPA was administered intravenously, using an automated injector. A test bolus method was used for timing of the bolus relative to the beginning of the data acquisition. Intra-arterial CA was used as the standard of reference in all patients. Separate interpretations of the CA and MRA results were made by two different pairs of radiologists, who were each blinded to the results of the other exam. RESULTS. In all, 31 of 33 accessory renal arteries were correctly identified. All 205 main renal arteries were seen with MRA, Of 65 significant stenoses identified on CA, 61 were correctly identified and graded by MRA, Sensitivity and specificity values for the assessment of significant renal arterial lesions were 93% and 90%, respectively. CONCLUSIONS. Breath-hold, contrast-enhanced 3D MRA allows for the reliable assessment of renal arterial morphology and pathologic states.
引用
收藏
页码:653 / 659
页数:7
相关论文
共 24 条
[1]   Renal artery stenosis: Value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil [J].
DeCobelli, F ;
Mellone, R ;
Salvioni, M ;
Vanzulli, A ;
Sironi, S ;
Manunta, P ;
Lanzani, C ;
Bianchi, G ;
DelMaschio, A .
RADIOLOGY, 1996, 201 (03) :697-703
[2]   RENAL-ARTERIES - EVALUATION WITH OPTIMIZED 2D AND 3D TIME-OF-FLIGHT MR-ANGIOGRAPHY [J].
FELLNER, C ;
STROTZER, M ;
GEISSLER, A ;
KOHLER, SM ;
KRAMER, BK ;
SPIES, V ;
HELD, P ;
GMEINWIESER, J .
RADIOLOGY, 1995, 196 (03) :681-687
[3]   Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels [J].
Gilfeather, M ;
Holland, GA ;
Siegelman, ES ;
Schanll, MD ;
Axel, L ;
Carpenter, JP ;
Golden, MA .
RADIOGRAPHICS, 1997, 17 (02) :423-432
[4]   Diagnosis of renovascular hypertension: Feasibility of captopril-sensitized dynamic MR imaging and comparison with captopril scintigraphy [J].
Grenier, N ;
Trillaud, H ;
Combe, C ;
Degreze, P ;
Jeandot, R ;
Gosse, P ;
Douws, C ;
Palussiere, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :835-843
[5]   Diagnostic impact of four postprocessing techniques in evaluating contrast-enhanced three-dimensional MR angiography [J].
Hany, TF ;
Schmidt, M ;
Davis, CP ;
Göhde, SC ;
Debatin, JF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) :907-912
[6]   Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography [J].
Hany, TF ;
Debatin, JF ;
Leung, DA ;
Pfammatter, T .
RADIOLOGY, 1997, 204 (02) :357-362
[7]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[8]  
Johnson DBS, 1997, MAGN RESON IMAGING, V15, P13
[9]   Breath-hold, contrast-enhanced, three-dimensional MR angiography [J].
Leung, DA ;
McKinnon, GC ;
Davis, CP ;
Pfammatter, T ;
Krestin, GP ;
Debatin, JF .
RADIOLOGY, 1996, 200 (02) :569-571
[10]   Ability of a phase shift US contrast agent to improve imaging of the main renal arteries [J].
Melany, ML ;
Grant, EG ;
Duerinckx, AJ ;
Watts, TM ;
Levine, BS .
RADIOLOGY, 1997, 205 (01) :147-152