Intracranial black-blood MR angiography with high-resolution 3D fast spin echo

被引:47
作者
Alexander, AL
Buswell, HR
Sun, Y
Chapman, BE
Tsuruda, TS
Parker, DL
机构
[1] Univ Utah, MIRL, Ctr Adv Med Technol, Dept Radiol, Salt Lake City, UT 84108 USA
[2] GE, Med Syst, MR Adv Applicat, Waukesha, WI USA
关键词
MRA; vessels; black-blood; three-dimensional fast spin echo;
D O I
10.1002/mrm.1910400216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional fast spin-echo (3DFSE) techniques are promising for black-blood imaging of cerebral vessels. In this study, flow-related signal dephasing was demonstrated as the primary mechanism for blood signal attenuation, Parameter optimization of TR (1500 to 3000 ms), receiver bandwidth (25 to 31.25 kHz), effective TE (25.7 to 30.1 ms), and ETL (7 to 8) was accomplished by making measurements of vessel-to-tissue contrast-to-noise ratios on vessels. A comparison of high-resolution 3DFSE and 3DTOF magnetic resonance angiography demonstrated that 3DFSE can generate images with equivalent or better small vessel detail than conventional techniques. 3DFSE black-blood techniques may provide improved sensitivity of small arteries and veins with slow or in-plane flow and immunity to flow-related distortions. Future studies with optimized parameters will determine the clinical efficacy of this technique.
引用
收藏
页码:298 / 310
页数:13
相关论文
共 24 条
[1]  
ALEXANDER AL, 1996, P ISMRM 4 ANN M NEW, P580
[2]   Observer performance methodologies for evaluating blood vessel visibility in MR angiograms using accurate geometric registration to high resolution x-ray angiograms [J].
Chapman, BE ;
Sanderson, AR ;
Goodrich, KC ;
Alexander, AL ;
Blatter, DD ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :519-529
[3]   HIGH-SPEED BLACK BLOOD IMAGING OF VESSEL STENOSIS IN THE PRESENCE OF PULSATILE FLOW [J].
CHIEN, D ;
GOLDMANN, A ;
EDELMAN, RR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04) :437-441
[4]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[5]   CONTRAST-TO-NOISE-RATIO MEASUREMENTS IN 3-DIMENSIONAL MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DU, YP ;
PARKER, DL ;
DAVIS, WL ;
BLATTER, DD .
INVESTIGATIVE RADIOLOGY, 1993, 28 (11) :1004-1009
[6]   EXTRACRANIAL CAROTID ARTERIES - EVALUATION WITH BLACK BLOOD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MATTLE, HP ;
WALLNER, B ;
BAJAKIAN, R ;
KLEEFIELD, J ;
KENT, C ;
SKILLMAN, JJ ;
MENDEL, JB ;
ATKINSON, DJ .
RADIOLOGY, 1990, 177 (01) :45-50
[7]   FAST SELECTIVE BLACK BLOOD MR IMAGING [J].
EDELMAN, RR ;
CHIEN, D ;
KIM, D .
RADIOLOGY, 1991, 181 (03) :655-660
[8]  
FERNICONE JR, 1996, P ISMRM 4 ANN M NEW, P574
[9]  
FUKATSU H, 1995, P ISMRM 3 ANN M NIC, P1279
[10]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233