Radioreceptor assay for sirolimus

被引:10
作者
Goodyear, N
Napoli, KL
Murthy, JN
Kahan, BD
Soldin, SJ
机构
[1] CHILDRENS NATL MED CTR,DEPT LAB MED,WASHINGTON,DC 20010
[2] CATHOLIC UNIV AMER,DEPT BIOL,WASHINGTON,DC 20064
[3] UNIV TEXAS,HLTH SCI CTR,DEPT SURG,DIV IMMUNOL & ORGAN TRANSPLANTAT,HOUSTON,TX
[4] GEORGE WASHINGTON UNIV,DEPT PATHOL,WASHINGTON,DC
[5] GEORGE WASHINGTON UNIV,DEPT PEDIAT,WASHINGTON,DC 20052
关键词
immunophilins; rapamycin; radioreceptor assay; immunosuppression;
D O I
10.1016/0009-9120(96)00071-9
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To develop a radioreceptor assay (RRA) for sirolimus (rapamycin, RAPA). Methods: A direct methanol extraction was used to prepare 45 patient samples for the RRA. Results were compared to the results obtained previously using high-performance liquid chromatography (HPLC). Between-run precision, recovery, and drug interference studies were also performed. Results: The RRA is sensitive to 1.0 mu g/L RAPA equivalents in whole blood. Comparison with HPLC yielded a correlation coefficient for 45 patient samples of 0.977. Between-run precision at 2.5, 7.5, 12.5, and 20 mu g/L showed coefficients of variation (CVs) of 12.9, 9.2, 8.5, and 5.9%, respectively. Recoveries from the extraction procedure were 93% at 7.5 mu g/L and 103% at 12.5 mu g/L. Drug interference studies showed no interference in the RRA by cyclosporine (CsA), dexamethasone, prednisone, or methotrexate. Conclusion: We have demonstrated that the RRA for RAPA correlates well with HPLC, and has excellent precision and recovery. The procedure is far less time-consuming and complex than HPLC and has potential for automation.
引用
收藏
页码:457 / 460
页数:4
相关论文
共 29 条
[21]   SAMPLE CLEANUP AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC TECHNIQUES FOR MEASUREMENT OF WHOLE-BLOOD RAPAMYCIN CONCENTRATIONS [J].
NAPOLI, KL ;
KAHAN, BD .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 654 (01) :111-120
[22]   Receptor assays in the clinical laboratory [J].
Soldin, SJ .
CLINICAL BIOCHEMISTRY, 1996, 29 (05) :439-444
[23]  
SOLDIN SJ, 1994, TRANSPLANT P, V26, P2814
[24]  
SOLDIN SJ, 1994, Patent No. 5372772
[25]  
SVENSSON JO, 1996, IN PRESS THER DRUG M
[26]   RAPAMYCIN (AY-22,989), A NEW ANTIFUNGAL ANTIBIOTIC .1. TAXONOMY OF PRODUCING STREPTOMYCETE AND ISOLATION OF ACTIVE PRINCIPLE [J].
VEZINA, C ;
KUDELSKI, A ;
SEHGAL, SN .
JOURNAL OF ANTIBIOTICS, 1975, 28 (10) :721-726
[27]  
WANG CP, 1995, J LIQ CHROMATOGR, V18, P2259
[28]   MEASUREMENT OF RAPAMYCIN IN WHOLE-BLOOD USING REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
YATSCOFF, RW ;
FARACI, C ;
BOLINGBROKE, P .
THERAPEUTIC DRUG MONITORING, 1992, 14 (02) :138-141
[29]   THERAPEUTIC MONITORING OF RAPAMYCIN - A NEW IMMUNOSUPPRESSIVE DRUG [J].
YATSCOFF, RW ;
LEGATT, DF ;
KNETEMAN, NM .
THERAPEUTIC DRUG MONITORING, 1993, 15 (06) :478-482