Determination of selenium by tungsten coil atomic absorption spectrometry using iridium as a permanent chemical modifier

被引:42
作者
Hou, XD [1 ]
Yang, Z [1 ]
Jones, BT [1 ]
机构
[1] Wake Forest Univ, Dept Chem, Winston Salem, NC 27109 USA
关键词
atomic absorption spectrometry; electrothermal atomization; tungsten-coil atomizer; permanent chemical modifier; iridium; selenium;
D O I
10.1016/S0584-8547(00)00305-0
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Permanent chemical modifiers have been shown to prolong graphite tube lifetime while reducing the furnace cycle time, thus improving cost-effectiveness. In this work, iridium is used as a permanent chemical modifier for the first time in the determination of selenium by tungsten-coil atomic absorption spectrometry (W-Coil AAS). The iridium modifier is thermally coated onto the tungsten coil. After coating, the coil can be used for 300-400 firings without further application of the modifier. Thermal treatment with iridium permits operating with higher pyrolysis temperature and coil lifetime is extended up to 1600 firings. The sensitivity and linearity of the method is improved, and the analytical procedure allows the use of analyte solutions containing up to 8% nitric acid. The short-term stability of the absorbance measurements is demonstrated by the reproducibility in the measurements of a Se amount (6 ng) 30 times higher than the limit of detection (0.2 ng). A 7% relative standard deviation (R.S.D) was observed for 10 consecutive measurements of 6 ng Se. The long-term stability is almost as good: less than 9% R.S.D. over a 3-week period and 1500 firings. The surface of the tungsten-coil treated with iridium is examined before and after intensive use by scanning electron microscopy. Finally, the thermal treatment of the tungsten-coil with iridium appears to delay the appearance of selenium atoms by approximately 0.2 s although the integrated absorbance measurements are unaffected. The magnitude of delay decreases with coil age. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:203 / 214
页数:12
相关论文
共 37 条
[1]   Determination of cadmium with a portable, battery-powered tungsten coil atomic absorption spectrometer [J].
Batchelor, JD ;
Thomas, SE ;
Jones, BT .
APPLIED SPECTROSCOPY, 1998, 52 (08) :1086-1091
[2]   SIMPLE LOW-COST TUNGSTEN-COIL ATOMIZER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BERNDT, H ;
SCHALDACH, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :709-712
[3]   Chemical modifiers in a tungsten coil electrothermal atomizer. Part 1. Determination of lead in hair and blood [J].
Bruhn, CG ;
Neira, JY ;
Valenzuela, GD ;
Nobrega, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (01) :29-35
[4]   Determination of cadmium in hair and blood by tungsten coil electrothermal atomic absorption spectrometry with chemical modifiers [J].
Bruhn, CG ;
Neira, JY ;
Valenzuela, GD ;
Nóbrega, JA .
TALANTA, 1999, 48 (03) :537-549
[5]   Monitoring of nitrogen gas purity by the hot filament method [J].
Buhlmann, HJ ;
Ilegems, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07) :2871-2877
[6]   Optimization of electrochemical deposition of noble metals for permanent modification in graphite furnace atomic absorption spectrometry [J].
Bulska, E ;
Liebert-Ilkowska, K ;
Hulanicki, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1057-1062
[7]   Noble metals as permanent modifiers for the determination of mercury by electrothermal atomic absorption spectrometry [J].
Bulska, E ;
Kandler, W ;
Hulanicki, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (9-10) :1263-1270
[8]   DETERMINATION OF TOTAL CHROMIUM IN WHOLE-BLOOD, BLOOD COMPONENTS, BONE, AND URINE BY FAST FURNACE PROGRAM ELECTROTHERMAL ATOMIZATION AAS AND USING NEITHER ANALYTE ISOFORMATION NOR BACKGROUND CORRECTION [J].
GRANADILLO, VA ;
DEMACHADO, LP ;
ROMERO, RA .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3624-3631
[9]   Low-cost, modular electrothermal vaporization system for inductively coupled plasma atomic emission spectrometry [J].
Levine, K ;
Wagner, KA ;
Jones, BT .
APPLIED SPECTROSCOPY, 1998, 52 (09) :1165-1171
[10]   FAST FURNACE DETERMINATIONS OF ALUMINUM AND IRON IN BONE AND SOFT-TISSUES [J].
LIAN, L .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (02) :239-244