Backside polyethylene deformation in total knee arthroplasty

被引:21
作者
Akisue, T
Yamaguchi, M
Bauer, TW
Takikawa, S
Schils, JP
Yoshiya, S
Kurosaka, M
机构
[1] Cleveland Clin Fdn, Dept Anat Pathol, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Orthopaed Surg, Cleveland, OH 44195 USA
[3] Kobe Univ, Grad Sch Med, Dept Orthopaed Surg, Kobe, Hyogo 657, Japan
[4] Meiwa Hosp, Dept Orthopaed Surg, Hyogo, Japan
[5] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
关键词
total knee arthroplasty; polyethylene; wear; retrieved implants; osteolysis;
D O I
10.1016/S0883-5403(03)00255-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The clinical importance of polyethylene deformation between the tibial insert and base plate ("backside") is unclear. We used a serniquantitative scoring system to compare clinical and radiographic factors with articular and backside deformation of 106 retrieved polyethylene tibial inserts. Backside deformation was associated with polyethylene thickness and type of locking mechanism. Deformation of the articular surface correlated with femoral osteolysis (P=.05). The mean backside deformation score was 33% greater for implants from patients with osteolysis than for implants from patients without osteolysis (P=.07). Our study may be biased based on the types of implants available for study, but for this group of implants, we cannot conclude with 95% certainty that backside polyethylene deformation was clinically important as a cause of periprosthetic osteolysis or implant loosening. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:784 / 791
页数:8
相关论文
共 30 条
[11]  
2-I
[12]   Relationship between wear debris particles and polyethylene surface damage in primary total knee arthroplasty [J].
Hirakawa, K ;
Bauer, TW ;
Yamaguchi, M ;
Stulberg, BN ;
Wilde, AH .
JOURNAL OF ARTHROPLASTY, 1999, 14 (02) :165-171
[13]  
HIRAKAWA K, 1996, SEMIN ARTHROPLASTY, V7, P1
[14]   POLYETHYLENE AND METAL DEBRIS GENERATED BY NON-ARTICULATING SURFACES OF MODULAR ACETABULAR COMPONENTS [J].
HUK, OL ;
MANJULA, B ;
BETTS, F ;
RIMNAC, CM ;
LIEBERMAN, JR ;
HUO, MH ;
SALVATI, EA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (04) :568-574
[15]  
LEWIS PL, 1995, CLIN ORTHOP RELAT R, V321, P173
[16]   Wear of the polyethylene liner-metallic shell interface in modular acetabular components - An in vitro analysis [J].
Lieberman, JR ;
Kay, RM ;
Hamlet, WP ;
Park, SH ;
Kabo, JM .
JOURNAL OF ARTHROPLASTY, 1996, 11 (05) :602-608
[17]  
MALONEY WJ, 1992, J BONE JOINT SURG AM, V74, P864
[18]   DISTINGUISHING WEAR AND CREEP IN CLINICALLY RETRIEVED POLYETHYLENE INSERTS [J].
MCDONALD, MD ;
BLOEBAUM, RD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01) :1-7
[19]   IMPINGEMENT AND LOOSENING OF THE LONG POSTERIOR WALL ACETABULAR IMPLANT [J].
MURRAY, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :377-379
[20]  
PARKS NL, 1998, CLIN ORTHOP RELAT R, V356, P10