On-chip thermopneumatic pressure for discrete drop pumping

被引:65
作者
Handique, K
Burke, DT
Mastrangelo, CH
Burns, MA [1 ]
机构
[1] Univ Michigan, Dept Chem Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Human Genet, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Inst Gerontol, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac000711f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A class of "lab-on-a-chip" devices use external air pressure for pumping discrete drops in a microchannel network. External air connectors can be cumbersome and are real-estate intensive. We have developed an on-chip technique to generate pressures required for metering and pumping of nanoliter-volume discrete drops. This is achieved by heating of trapped air in a pressure-generating chamber, The pressure-generating chamber is connected to the point of pressure application in the liquid-conveying microchannel through an air-delivery channel. The trapped air volume on the order of 100 nL is heated by resistive metal heaters by tens of degrees celcius to generate air pressures on the order of 7.5 kN/m(2). The rate of discrete drop pumping is electronically controlled in the microchannel device by controlling the rate of air heating. Flow rates on the order of 20 nL/s are obtained in the microchannel (300 mum x 30 mum) by heating the air chamber at the rate of similar to6 degreesC/s. In this paper, we describe the design, fabrication, and operation of this new technique of generating on-chip air pressure, used for metering and pumping nanoliter discrete drops in microchannels.
引用
收藏
页码:1831 / 1838
页数:8
相关论文
共 20 条
[1]  
Anderson RC, 1997, TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P477, DOI 10.1109/SENSOR.1997.613690
[2]   A closed-loop controlled electrochemically actuated micro-dosing system [J].
Böhm, S ;
Timmer, B ;
Olthuis, W ;
Bergveld, P .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2000, 10 (04) :498-504
[3]  
BOONE TD, 1998, P SOL STAT SENS ACT, P87
[4]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[5]   Microfabricated structures for integrated DNA analysis [J].
Burns, MA ;
Mastrangelo, CH ;
Sammarco, TS ;
Man, FP ;
Webster, JR ;
Johnson, BN ;
Foerster, B ;
Jones, D ;
Fields, Y ;
Kaiser, AR ;
Burke, DT .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (11) :5556-5561
[6]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[7]  
GREEN D, 1984, PERRYS CHEM ENG HDB, P2
[8]   Nanoliter liquid metering in microchannels using hydrophobic patterns [J].
Handique, K ;
Burke, DT ;
Mastrangelo, CH ;
Burns, MA .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4100-4109
[9]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[10]   Handling of picoliter liquid samples in a poly(dimethylsiloxane)-based microfluidic device [J].
Hosokawa, K ;
Fujii, T ;
Endo, I .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4781-4785