Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation

被引:86
作者
Stewart, TD
Tipper, JL
Insley, G
Streicher, RM
Ingham, E
Fisher, J
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Div Microbiol, Leeds LS2 9JT, W Yorkshire, England
[3] Stryker SA, Sci & Clin Affairs, CH-8800 Thawil, Switzerland
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS | 2003年 / 66B卷 / 02期
关键词
hip prostheses; alumina matrix composite; wear; microseparation; simulator;
D O I
10.1002/jbm.b.10035
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The purpose of this study was to evaluate the long-term wear performance of alumina matrix composite (AMC) heads against alumina matrix composite inserts and alumina matrix composite heads against alumina (Al) inserts with the use of a hip-joint simulator incorporating severe swing phase joint microseparation. The wear of AMC on Al produced an average wear rate of 0.61 mm(3)/Million cycles over the 5-million-cycle test duration. The wear of AMC on AMC produced an average wear rate of 0.16 mm(3)/million cycles over the 5-million-cycle test duration. Both the AMC on alumina and AMC on AMC produced significantly lower wear than previously tested HIPed alumina, where an average wear rate of 1.84 mm(3)/million cycles was reported over 5 million cycles. The wear mechanisms and wear debris of AMC on AMC and AMC on Al were similar to those observed in previous alumina retrieval studies with stripe wear caused by intragranular fracture and wear debris consisting of predominantly uniform 10-20-nm-sized particles and a few irregular particles up to 3 mum in size. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 17 条
[1]
A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) :455-467
[2]
Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements [J].
Clarke, IC ;
Good, V ;
Williams, P ;
Schroeder, D ;
Anissian, L ;
Stark, A ;
Oonishi, H ;
Schuldies, J ;
Gustafson, G .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H4) :331-347
[3]
Ceramics in orthopaedics [J].
Hamadouche, M ;
Sedel, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1095-1099
[4]
HATTON A, 2000, 6 WORLD C BIOM HAW U, P1188
[5]
An in vivo determination of total hip arthroplasty pistoning during activity [J].
Lombardi, AV ;
Mallory, TH ;
Dennis, DA ;
Komistek, RD ;
Fada, RA ;
Northcut, EJ .
JOURNAL OF ARTHROPLASTY, 2000, 15 (06) :702-709
[6]
Wear of retrieved ceramic THA components - Four matched pairs retrieved after 5-13 years in service [J].
Magnissalis, EA ;
Xenakis, TA ;
Zacharis, C .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05) :593-598
[7]
Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty [J].
Morlock, M ;
Nassutt, R ;
Janssen, R ;
Willmann, G ;
Honl, M .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :1071-1074
[8]
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns [J].
Nevelos, J ;
Ingham, E ;
Doyle, C ;
Streicher, R ;
Nevelos, A ;
Walter, W ;
Fisher, J .
JOURNAL OF ARTHROPLASTY, 2000, 15 (06) :793-795
[9]
The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator [J].
Nevelos, JE ;
Ingham, E ;
Doyle, C ;
Nevelos, AB ;
Fisher, J .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (02) :141-144
[10]
NEVELOS JE, 2000, J BIOMATER, V20, P1833