摘要
An electronic tongue (ET) employing the transient response of an array of non-specific-response potentiometric sensors was developed for a quantitative application. A sequential injection analysis (SIA) system was used in order to automate its training and operation. This procedure takes profit of the dynamic nature of the sensor's response, which can be of high information content, improving the discrimination ability between primary and interfering ions. This work presents the extraction of significant information contained in the pulse sample transient response of a sensor array formed by eight sensors. The tool employed was the fast Fourier transform (FFT) analysis, from which three coefficients per sensor were fed into an artificial neural network (ANN) model. The studied case was the multidetermination of quaternary mixtures of Ca2+, Mg2+, Na+ and K+ in water samples, showing improved resolution when compared to classical ET approaches. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 28 条
[21]   Response time of ion-selective electrodes -: Current usage versus IUPAC recommendations [J].
Maccà, C .
ANALYTICA CHIMICA ACTA, 2004, 512 (02) :183-190
[22]   Application of the wavelet transform coupled with artificial neural networks for quantification purposes in a voltammetric electronic tongue [J].
Moreno-Barón, L ;
Cartas, R ;
Merkoçi, A ;
Alegret, S ;
del Valle, M ;
Leija, L ;
Hernandez, PR ;
Muñoz, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01) :487-499
[23]   A flow injection system based on chalcogenide glass sensors for the determination of heavy metals [J].
Mortensen, J ;
Legin, A ;
Ipatov, A ;
Rudnitskaya, A ;
Vlasov, Y ;
Hjuler, K .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :273-277
[24]   DATA-PROCESSING FOR AMPEROMETRIC SIGNALS [J].
SIMONS, J ;
BOS, M ;
VANDERLINDEN, WE .
ANALYST, 1995, 120 (04) :1009-1012
[25]   Potentiometric selectivity coefficients of ion-selective electrodes Part III.: Organic ions -: (IUPAC technical report) [J].
Umezawa, Y ;
Bühlmann, P ;
Umezawa, K ;
Hamada, N .
PURE AND APPLIED CHEMISTRY, 2002, 74 (06) :995-1099
[26]   Potentiometric selectivity coefficients of ion-selective electrodes Part II.: Inorganic anions -: (IUPAC technical report) [J].
Umezawa, Y ;
Umezawa, K ;
Bühlmann, P ;
Hamada, N ;
Aoki, H ;
Nakanishi, J ;
Sato, M ;
Xiao, KP ;
Nishimura, Y .
PURE AND APPLIED CHEMISTRY, 2002, 74 (06) :923-994
[27]   Potentiometric selectivity coefficients of ion-selective electrodes Part I.: Inorganic cations -: (Technical report) [J].
Umezawa, Y ;
Bühlmann, P ;
Umezawa, K ;
Tohda, K ;
Amemiya, S .
PURE AND APPLIED CHEMISTRY, 2000, 72 (10) :1851-2082
[28]   Nonspecific sensor arrays ("electronic tongue") for chemical analysis of liquids (IUPAC Technical Report) [J].
Vlasov, Y ;
Legin, A ;
Rudnitskaya, A ;
Di Natale, C ;
D'Amico, A .
PURE AND APPLIED CHEMISTRY, 2005, 77 (11) :1965-1983