Response time of ion-selective electrodes -: Current usage versus IUPAC recommendations

被引:113
作者
Maccà, C [1 ]
机构
[1] Univ Padua, Dept Chem Sci, I-35131 Padua, Italy
关键词
ion-selective electrodes; response time; IUPAC recommendations;
D O I
10.1016/j.aca.2004.03.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The current usage in evaluating the response speed of ion-selective electrodes is critically surveyed. Examination of the articles introducing new ISEs published in eight leading analytical and electroanalytical chemistry journals in the period 2000-2001 and of sparse articles appeared afterwards shows that the current IUPAC definition of response time, based on the differential quotient DeltaE/Deltat, is only used by a minority of authors. In its place, former IUPAC definitions, to be presently considered obsolete, or different expressions of the response speed are commonly preferred. In most instances, the reported data do not describe adequately the electrode behaviour. Stricter adherence to the most recent IUPAC recommendation, which is more rational and nearly related with the practical reading time, is to be stimulated. Wider use of faithful emf versus time plots also deserves to be encouraged. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:183 / 190
页数:8
相关论文
共 74 条
[1]   New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury [J].
Abbas, MN ;
Mostafa, GAE .
ANALYTICA CHIMICA ACTA, 2003, 478 (02) :329-335
[2]   PVC membrane ion selective electrode for the determination of pentachlorophenol in water, wood and soil using tetrazolium pentachlorophenolate [J].
Abbas, MN ;
Mostafa, GAE ;
Homoda, AMA .
TALANTA, 2001, 55 (03) :647-656
[3]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[4]   On the static and dynamic selectivity study of a sodium sensor [J].
Attari, M ;
Fabry, P .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (04) :732-735
[5]   SELECTIVITY OF ION-SENSITIVE BULK OPTODES [J].
BAKKER, E ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1805-1812
[6]   Electrochemical sensors [J].
Bakker, E ;
Telting-Diaz, M .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2781-2800
[7]   Ionophore-based membrane electrodes: new analytical concepts and non-classical response mechanisms [J].
Bakker, E ;
Meyerhoff, ME .
ANALYTICA CHIMICA ACTA, 2000, 416 (02) :121-137
[8]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[9]   Synthesis of an ammonium ionophore and its application in a planar ion-selective electrode [J].
Benco, JS ;
Nienaber, HA ;
McGimpsey, WG .
ANALYTICAL CHEMISTRY, 2003, 75 (01) :152-156
[10]   Tripodal ionophore with sulfate recognition properties for anion-selective electrodes [J].
Berrocal, MJ ;
Cruz, A ;
Badr, IHA ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5295-5299