Complications associated with generator replacement in response to device advisories

被引:35
作者
Costea, Alexandru [1 ]
Rardon, David P. [1 ]
Padanilam, Benzy J. [1 ]
Fogel, Richard I. [1 ]
Prystowsky, Eric N. [1 ]
机构
[1] St Vincent Hosp, Dept Cardiol, Care Grp, Indianapolis, IN 46260 USA
关键词
implantable defibrillators; pacemakers; device complications; device failure;
D O I
10.1111/j.1540-8167.2007.01047.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Complications Associated with Generator Replacement. Introduction: Device recalls create problems for patients and physicians, for the risks associated with replacement may be greater than the device failure rate. In 2005, Medtronic, Guidant, and St. Jude had implantable cardioverter defibrillator (ICD) recalls on several of their devices. There were no national standards to guide physicians on the management of such patients. We report the reasons for and outcomes of ICD and pacemaker generator changes from our practice resulting from these advisories. Methods and Results: After an advisory was issued, the patients with an affected device were contacted, evaluated in the office by one of the electrophysiologists in our group, and a management plan was determined. Two hundred and twenty-two of 1,039 (Medtronic 273, Guidant 766) (21.4%) patients with advisory devices underwent device replacement. Nine minor complications occurred: hematoma managed conservatively (n = 6); local discomfort (n = 1); and incisional infections treated successfully with oral antibiotics (n = 2). Major complications occurred in nine patients (4.1%). Four atrial leads were damaged, two of which were repaired, one during the same procedure and the other at a later date. One patient required a reoperation to tighten a loose ventricular lead set screw. Hematoma requiring evacuation occurred in one patient, and pocket revision was necessary in two patients secondary to severe discomfort due to the positioning of the device in the pocket. One patient had a cerebrovascular accident preoperatively. There were no perioperative deaths or infections requiring system removal. Conclusion: Even with experienced operators complications can occur when replacing generators for a device recall. Careful risk assessment for each individual patient should be performed and efforts made to minimize generator changes.
引用
收藏
页码:266 / 269
页数:4
相关论文
共 9 条
[1]   The relation between patients' outcomes and the volume of cardioverter-defibrillator implantation procedures performed by physicians treating medicare beneficiaries [J].
Al-Khatib, SM ;
Lucas, FL ;
Jollis, JG ;
Malenka, DJ ;
Wennberg, DE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (08) :1536-1540
[2]   Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996 [J].
Byrd, CL ;
Wilkoff, BL ;
Love, CJ ;
Sellers, TD ;
Turk, KT ;
Reeves, R ;
Young, R ;
Crevey, B ;
Kutalek, SP ;
Freedman, R ;
Friedman, R ;
Trantham, J ;
Watts, M ;
Schutzman, J ;
Oren, J ;
Wilson, J ;
Gold, F ;
Fearnot, NE ;
Van Zandt, HJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (09) :1348-1357
[3]   Recommendations from the Heart Rhythm Society Task Force on device performance policies and guidelines [J].
Carlson, Mark D. ;
Wilkoff, Bruce L. ;
Maisel, William H. ;
Ellenbogen, Kenneth A. ;
Saxon, Leslie A. ;
Prystowsky, Eric N. ;
Alpert, Joseph S. ;
Cain, Michael E. ;
Ching, Elizabeth A. ;
Curtis, Anne B. ;
Davies, D. Wyn ;
Hammill, Stephen C. ;
Hauser, Robert G. ;
Lampert, Rachel ;
Zipes, Douglas P. .
HEART RHYTHM, 2006, 3 (10) :1250-1273
[4]   Optimal combination of discriminators for differentiating ventricular from supraventricular tachycardia by dual-chamber defibrillators [J].
Glikson, M ;
Swerdlow, CD ;
Gurevitz, OT ;
Daoud, E ;
Shivkumar, K ;
Wilkoff, B ;
Shipman, T ;
Friedman, PA .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (07) :732-739
[5]   Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories [J].
Gould, PA ;
Krahn, AD .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (16) :1907-1911
[6]   Pacemaker and ICD generator reliability - Meta-analysis of device registries [J].
Maisel, WH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (16) :1929-1934
[7]   Pacemaker and ICD generator malfunctions - Analysis of food and drug administration annual reports [J].
Maisel, WH ;
Moynahan, M ;
Zuckerman, BD ;
Gross, TP ;
Tovar, OH ;
Tillman, DB ;
Schultz, DB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (16) :1901-1906
[8]  
*MARQ ICD CRT D, 2005, MEDTR PHYS LETT
[9]   Pacemaker and ICD malfunction - An incomplete picture [J].
Wilkoff, BL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (16) :1944-1946