Mass analysis of mobility-selected ion populations using dual gate, ion mobility, quadrupole ion trap mass spectrometry

被引:67
作者
Clowers, BH
Hill, HH [1 ]
机构
[1] Washington State Univ, Dept Chem, Pullman, WA 99164 USA
[2] Washington State Univ, Ctr Multiphase Environm Res, Pullman, WA 99164 USA
关键词
D O I
10.1021/ac050700s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrospray ionization, dual gate, ion mobility, quadrupole ion trap mass spectrometer (ESI-DG-IM-QIT-MS) was constructed and evaluated for its ability to select mobility-filtered ions prior to mass analysis. While modification of the common signal-averaged ion mobility experiment was required, no modifications to the QIT were necessary. The dual gate scanning mode of operation was used to acquire mobility spectra, whereas the single mobility monitoring experiment selectively filtered ions for concentration and subsequent fragmentation within the QIT. Ion mobility separation of positively charged peptides and negatively charged carbohydrates, followed by MS fragmentation, was demonstrated. For a 1-min acquisition time, it was possible to obtain complete de novo sequence information for the examined peptides. Fragmentation of the negative carbohydrate chlorine adducts yielded ions characteristic of cross-ring and glycosidic bond cleavage. Previous unions of atmospheric pressure ion mobility and mass spectrometry have been limited in their ability to reproducibly obtain MSn data for mobility separation ions. The union of high-pressure ion mobility with quadrupole ion trap mass spectrometry presents the unique opportunity to obtain more detailed information regarding the chemistries of gas-phase ions.
引用
收藏
页码:5877 / 5885
页数:9
相关论文
共 47 条
[31]   Evaluation of opiate separation by high-resolution electrospray ionization-ion mobility spectrometry/mass spectrometry [J].
Matz, LM ;
Hill, HH .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1664-1669
[32]   THEORY OF PLASMA CHROMATOGRAPHY GASEOUS ELECTROPHORESIS - REVIEW [J].
REVERCOMB, HE ;
MASON, EA .
ANALYTICAL CHEMISTRY, 1975, 47 (07) :970-983
[33]   Analysis of protein mixtures by matrix-assisted laser desorption ionization-ion mobility-orthogonal-time-of-flight mass spectrometry [J].
Ruotolo, BT ;
Gillig, KJ ;
Stone, EG ;
Russell, DH ;
Fuhrer, K ;
Gonin, M ;
Schultz, JA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 219 (01) :253-267
[34]   Distinguishing between phosphorylated and nonphosphorylated peptides with ion mobility-mass spectrometry [J].
Ruotolo, BT ;
Verbeck, GF ;
Thomson, LM ;
Woods, AS ;
Gillig, KJ ;
Russell, DH .
JOURNAL OF PROTEOME RESEARCH, 2002, 1 (04) :303-306
[35]   CORONASPRAY NEBULIZATION AND IONIZATION OF LIQUID SAMPLES FOR ION MOBILITY SPECTROMETRY [J].
SHUMATE, CB ;
HILL, HH .
ANALYTICAL CHEMISTRY, 1989, 61 (06) :601-606
[36]   MEASURING THE RESOLVING POWER OF ION MOBILITY SPECTROMETERS [J].
SIEMS, WF ;
WU, C ;
TARVER, EE ;
HILL, HH ;
LARSEN, PR ;
MCMINN, DG .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4195-4201
[37]  
SKOOGDA, 1998, PRINCIPLES INSTRUMEN, P13
[38]   Nanoflow LCAMS-MS and LCAMS-CID/MS of protein mixtures [J].
Sowell, RA ;
Koeniger, SL ;
Valentine, SJ ;
Moon, MH ;
Clemmer, DE .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (09) :1341-1353
[39]   Electrospray ionization with ambient pressure ion mobility separation and mass analysis by orthogonal time-of-flight mass spectrometry [J].
Steiner, WE ;
Clowers, BH ;
Fuhrer, K ;
Gonin, M ;
Matz, LM ;
Siems, WF ;
Schultz, AJ ;
Hill, HH .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (23) :2221-2226
[40]   Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis [J].
Sysoev, A ;
Adamov, A ;
Vildanoja, J ;
Ketoja, RA ;
Kostiainen, R ;
Kotiaho, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (24) :3131-3139