Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease

被引:371
作者
Boushel, R
Langberg, H
Olesen, J
Gonzales-Alonzo, J
Bülow, J
Kjær, M
机构
[1] Concordia Univ, Dept Exercise Sci, Montreal, PQ H47 1RB, Canada
[2] Univ Copenhagen, Bispebjerg Hosp, Sports Med Res Unit, Copenhagen Muscle Res Ctr, Copenhagen, Denmark
关键词
D O I
10.1034/j.1600-0838.2001.110404.x
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Near infrared spectroscopy (NIRS) is becoming a widely used research instrument to measure tissue oxygen (Oz) status non-invasively, Continuous-wave spectrometers are the most commonly used devices, which provide semiquantitative changes in oxygenated and deoxygenated hemoglobin in small blood vessels (arterioles, capillaries and venules), Refinement of NIRS hardware and the algorithms used to deconvolute the light absorption signal have improved the resolution and validity of cytochrome oxidase measurements. NIRS has been applied to measure oxygenation in a variety of tissues including muscle, brain and connective tissue, and more recently it has been used in the clinical setting to assess circulatory and metabolic abnormalities. Quantitative measures of blood flow are also possible using NIRS and a light-absorbing tracer, which can be applied to evaluate circulatory responses to exercise along with the assessment of tissue O-2 saturation. The venular O-2 saturation can be estimated with NIRS by applying venous occlusion and measuring changes in oxygenated vs. total hemoglobin. These various measurements provide the opportunity to evaluate several important metabolic and circulatory patterns in very localized regions of tissue and may be fruitful in the study of occupational syndromes and a variety of diseases.
引用
收藏
页码:213 / 222
页数:10
相关论文
共 64 条
[31]   Dissociation between muscle metabolism and oxygen kinetics during recovery from exercise in patients with chronic heart failure [J].
Hanada, A ;
Okita, K ;
Yonezawa, K ;
Ohtsubo, M ;
Kohya, T ;
Murakami, T ;
Nishijima, H ;
Tamura, M ;
Kitabatake, A .
HEART, 2000, 83 (02) :161-166
[32]   Differential sympathetic neural control of oxygenation in resting and exercising human skeletal muscle [J].
Hansen, J ;
Thomas, GD ;
Harris, SA ;
Parsons, WJ ;
Victor, RG .
JOURNAL OF CLINICAL INVESTIGATION, 1996, 98 (02) :584-596
[33]   Tissue oxygenation by near-infrared spectroscopy and muscle blood flow during isometric contractions of the forearm [J].
Hicks, A ;
McGill, S ;
Hughson, RL .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 1999, 24 (03) :216-230
[34]   Near-infrared estimation of O-2 supply and consumption in forearm muscles working at varying intensity [J].
Homma, S ;
Eda, H ;
Ogasawara, S ;
Kagaya, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (04) :1279-1284
[35]   NONINVASIVE, INFRARED MONITORING OF CEREBRAL AND MYOCARDIAL OXYGEN SUFFICIENCY AND CIRCULATORY PARAMETERS [J].
JOBSIS, FF .
SCIENCE, 1977, 198 (4323) :1264-1267
[36]   AN OBJECTIVE ASSESSMENT OF INTERMITTENT CLAUDICATION BY NEAR-INFRARED SPECTROSCOPY [J].
KOMIYAMA, T ;
SHIGEMATSU, H ;
YASUHARA, H ;
MUTO, T .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (03) :294-296
[37]   Near infrared spectroscopy for noninvasive assessment of claudication [J].
Kooijman, HM ;
Hopman, MTE ;
Colier, WNJM ;
vanderVliet, JA ;
Oeseburg, B .
JOURNAL OF SURGICAL RESEARCH, 1997, 72 (01) :1-7
[38]   Noninvasive measurement of regional cerebral blood flow by near-infrared spectroscopy and indocyanine green [J].
Kuebler, WM ;
Sckell, A ;
Habler, O ;
Kleen, M ;
Kuhnle, GEH ;
Welte, M ;
Messmer, K ;
Goetz, AE .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1998, 18 (04) :445-456
[39]   NEAR-INFRARED MONITORING OF THE CEREBRAL-CIRCULATION [J].
KURTH, CD ;
STEVEN, JM ;
BENARON, D ;
CHANCE, B .
JOURNAL OF CLINICAL MONITORING, 1993, 9 (03) :163-170
[40]   Metabolism and inflammatory mediators in the peritendinous space measured by microdialysis during intermittent isometric exercise in humans [J].
Langberg, H ;
Skovgaard, D ;
Karamouzis, M ;
Bülow, J ;
Kjær, M .
JOURNAL OF PHYSIOLOGY-LONDON, 1999, 515 (03) :919-927