Flat-fixed dosing versus body surface area-based dosing of anticancer drugs in adults: Does it make a difference?

被引:113
作者
Mathijssen, Ron H. J. [1 ]
De Jong, Floris A. [1 ]
Loos, Walter J. [1 ]
van der Bol, Jessica M. [1 ]
Verweij, Jaap [1 ]
Sparreboom, Alex [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dr Daniel Den Hoed Canc Ctr, Dept Med Oncol, NL-3075 EA Rotterdam, Netherlands
关键词
BSA; flat-fixed dosing; pharmacokinetics; pharmacodynamics; individualized dosing; S-METHYLTRANSFERASE DEFICIENCY; CELL LUNG-CANCER; POPULATION PHARMACOKINETICS; DOSE CALCULATION; EPIRUBICIN PHARMACOKINETICS; RENAL-FUNCTION; SOLID TUMORS; IRINOTECAN; CHEMOTHERAPY; THERAPY;
D O I
10.1634/theoncologist.12-8-913
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The current practice of using body-surface area (BSA) in dosing anticancer agents was implemented in clinical oncology half a century ago. By correcting for BSA, it was generally assumed that cancer patients would receive a dose of a particular cytotoxic drug associated with an acceptable degree of toxicities without reducing the agent's therapeutic effect. More recently, doubt has arisen to this hypothesis, and for many drugs, the effects of BSA on the pharmacokinetics of these agents have therefore been studied retrospectively. In (by far) most cases, use of BSA does not reduce the interindividual variation in the pharmacokinetics of adults, and thus, a logical rationale for further use of this tool in dosing adults is lacking. As a result, alternative dosing strategies have been proposed in order to replace BSA-based dosing. Flat-fixed dosing regimens have been suggested, thereby avoiding potential dose calculation mistakes. As flat-fixed dosing does not typically lead to greater pharmacokinetic variability, it does not seem worse than using BSA-based dosing. While it provides a simplification, it can, however, be questioned whether to call this an improvement or not. The implementation of socalled genotyping and phenotyping strategies, and therapeutic drug monitoring, may probably be of more clinical value. In the end, the nonscientifically based BSA-based dosing strategy should be replaced by alternative strategies. Despite the lack of basic fundamentals, BSA-based dosing still seems "untouchable" in clinical oncology. Even when alternatives will be shown to be indisputably better, many hurdles will probably have to be overcome before physicians will be willing to ban BSA-based dosing.
引用
收藏
页码:913 / 923
页数:11
相关论文
共 85 条
[31]   Dosing strategies for anticancer drugs: the good, the bad and body-surface area [J].
Felici, A ;
Verweij, J ;
Sparreboom, A .
EUROPEAN JOURNAL OF CANCER, 2002, 38 (13) :1677-1684
[32]  
GEHAN EA, 1970, CANCER CHEMOTH REP 1, V54, P225
[33]   OBESITY AND THERAPY-RELATED TOXICITY IN PATIENTS TREATED FOR SMALL-CELL LUNG-CANCER [J].
GEORGIADIS, MS ;
STEINBERG, SM ;
HANKINS, LA ;
IHDE, DC ;
JOHNSON, BE .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1995, 87 (05) :361-366
[34]   Undertreatment of obese women receiving breast cancer chemotherapy [J].
Griggs, JJ ;
Sorbero, MES ;
Lyman, GH .
ARCHIVES OF INTERNAL MEDICINE, 2005, 165 (11) :1267-1273
[35]  
GROCHOW LB, 1990, J NATL CANCER I, V82, P323
[36]   Developing a new framework for dose calculation [J].
Gurney, H .
JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (10) :1489-1490
[37]   Dose calculation of anticancer drugs: A review of the current practice and introduction of an alternative [J].
Gurney, H .
JOURNAL OF CLINICAL ONCOLOGY, 1996, 14 (09) :2590-2611
[38]   Factors affecting epirubicin pharmacokinetics and toxicity: Evidence against using body-surface area for dose calculation [J].
Gurney, HP ;
Ackland, S ;
Gebski, V ;
Farrell, G .
JOURNAL OF CLINICAL ONCOLOGY, 1998, 16 (07) :2299-2304
[39]   GEOMETRIC METHOD FOR MEASURING BODY-SURFACE AREA - HEIGHT-WEIGHT FORMULA VALIDATED IN INFANTS, CHILDREN, AND ADULTS [J].
HAYCOCK, GB ;
SCHWARTZ, GJ ;
WISOTSKY, DH .
JOURNAL OF PEDIATRICS, 1978, 93 (01) :62-66
[40]  
Hon YY, 1998, CLIN CHEM, V44, P388