Variability of four-dimensional computed tomography patient models

被引:206
作者
Sonke, Jan-Jakob [1 ]
Lebesque, Joos [1 ]
Van Herk, Marcel [1 ]
机构
[1] Netherlands Canc Inst, Antoni Van Leeuwenhoek Hosp, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 70卷 / 02期
关键词
respiratory motion; geometric uncertainties; four-dimensional imaging; cone-beam CT; image-guided RT;
D O I
10.1016/j.ijrobp.2007.08.067
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify the interfractional variability in lung tumor trajectory and mean position during the course of radiation therapy. Methods and Materials: Repeat four-dimensional (4D) cone-beam computed tomography (CBCT) scans (median, nine scans/patient) routinely acquired during the course of treatment were analyzed for 56 patients with lung cancer. Tumor motion was assessed by using local rigid registration of a region of interest in the 3D planning CT to each phase in the 4D CBCT. Displacements of the mean tumor position relative to the planned position (baseline variations) were obtained by using time-weighted averaging of the motion curve. Results: The tumor trajectory shape was found to be stable interfractionally, with mean variability not exceeding 1 mm (1 SD) in each direction for the inhale and exhale phases. Interfractional baseline variations, however, were large, with 1.6- (left-right), 3.9- (cranial-caudal), and 2.8-mm (anterior-posterior) systematic variations (1 SD) and 1.2- (left-right), 2.4- (cranial-caudal) and 2.2-mm (anterior-posterior) random variations. Eliminating baseline variations by using soft-tissue guidance decreases planning target volume margins by approximately 50% compared with bony anatomy-driven protocols for conventional fractionation schemes. Conclusions: Systematic and random baseline variations constitute a substantial portion of the geometric variability present in the treatment of patients with lung cancer and require generous safety margins when relying on accurate setup/immobilization or bony anatomy-driven correction strategies. The 4D-CBCT has the ability to accurately monitor tumor trajectory shape and baseline variations and drive image-guided correction strategies that allows safe margin reduction. (C) 2008 Elsevier Inc.
引用
收藏
页码:590 / 598
页数:9
相关论文
共 33 条
[1]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[2]   MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning [J].
Blackall, J. M. ;
Ahmad, S. ;
Miquel, M. E. ;
McClelland, J. R. ;
Landau, D. B. ;
Hawkes, D. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (17) :4147-4169
[3]   Kilo-voltage cone-beam computed tomography setup measurements for lung cancer patients; First clinical results and comparison with electronic portal-imaging device [J].
Borst, Gerben R. ;
Sonke, Jan-Jakob ;
Betgen, Anja ;
Remeijer, Peter ;
Van Herk, Marcel ;
Lebesque, Joos V. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (02) :555-561
[4]   Observation of interfractional variations in lung tumor position using respiratory gated and ungated megavoltage cone-beam computed tomography [J].
Chang, Jenghwa ;
Mageras, Gig S. ;
Yorke, Ellen ;
De Arruda, Fernando ;
Sillanpaa, Jussi ;
Rosenzweig, Kenneth E. ;
Hertanto, Agung ;
Pham, Hai ;
Seppi, Edward ;
Pevsner, Alex ;
Ling, C. Clifton ;
Amols, Howard .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (05) :1548-1558
[5]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[6]   Is adaptive treatment planning required for stereotactic radiotherapy of stage I non-small-cell lung cancer? [J].
Haasbeek, Cornelis J. A. ;
Lagerwaard, Frank J. ;
Cuijpers, Johan P. ;
Slotman, Ben J. ;
Senan, Suresh .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (05) :1370-1374
[7]   Changes in the respiratory pattern during radiotherapy for cancer in the lung [J].
Hugo, G ;
Vargas, C ;
Liang, J ;
Kestin, L ;
Wong, JW ;
Yan, D .
RADIOTHERAPY AND ONCOLOGY, 2006, 78 (03) :326-331
[8]   Population and patient-specific target margins for 4D adaptive radiotherapy to account for intra- and inter-fraction variation in lung tumour position [J].
Hugo, Geoffrey D. ;
Yan, Di ;
Liang, Jian .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01) :257-274
[9]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[10]   4-dimensional computed tomography imaging and treatment planning [J].
Keall, P .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :81-90