The variation in output of symmetric, asymmetric and irregularly shaped wedged radiotherapy fields

被引:14
作者
Hounsell, AR
Wilkinson, JM
机构
[1] North Western Medical Physics, Christie Hospital, Holt Radium Institute
关键词
D O I
10.1088/0031-9155/41/10/021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A model for calculating the variation in output of symmetric, asymmetric and irregularly shaped wedged radiotherapy fields is presented. The variation in output from the treatment head when a wedge is used is calculated by dividing the output into a primary component and one due to scattered radiation. The scatter component is then further sub-divided into contributions from elements which have a 1 cm x 1 cm cross-sectional area at the isocentre. The scatter from each element is determined as the contribution from the head scatter component modified by the presence of the wedge and a contribution due to additional scattered radiation from the wedge. The relative intensity of the scattered radiation from the wedge is modelled using a simple first scatter approximation. In this approximation the magnitude of the scatter is given by a t exp(-mu t) function where t is the thickness of the wedge for the selected element. The magnitude of the primary component and the relative intensity of scatter from each element are then obtained by an iterative fit to measured data. The technique has been applied to two different internally mounted wedge designs, for a standard treatment head, two asymmetric treatment heads and two similar multileaf collimators, over a range of energies between 4 and 20 MV. Calculations agree with measured values over a range of field sizes and shapes to within 1.5%.
引用
收藏
页码:2155 / 2172
页数:18
相关论文
共 30 条
[11]   EXTENSION OF CONCEPT OF TISSUE-AIR RATIOS (TAR) TO HIGH-ENERGY X-RAY BEAMS [J].
HOLT, JG ;
LAUGHLIN, JS ;
MORONEY, JP .
RADIOLOGY, 1970, 96 (02) :437-&
[12]   TISSUE STANDARD RATIOS FOR IRREGULARLY SHAPED RADIOTHERAPY FIELDS [J].
HOUNSELL, AR ;
WILKINSON, JM .
BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (752) :629-634
[13]   SCATTERED PHOTONS PRODUCED BY BEAM-MODIFYING FILTERS [J].
HUANG, PH ;
CHIN, LM ;
BJARNGARD, BE .
MEDICAL PHYSICS, 1986, 13 (01) :57-63
[14]   PHOTON MASS ATTENUATION AND ENERGY-ABSORPTION COEFFICIENTS FROM 1 KEV TO 20 MEV [J].
HUBBELL, JH .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11) :1269-1290
[15]  
*ICRU INT COMM RAD, 1976, 24 ICRU INT COMM RAD
[16]   Effects of scatter generated by beam-modifying absorbers in megavoltage photon beams [J].
Islam, MK ;
VanDyk, J .
MEDICAL PHYSICS, 1995, 22 (12) :2075-2081
[17]   X-RAY SOURCES OF MEDICAL LINEAR ACCELERATORS - FOCAL AND EXTRA-FOCAL RADIATION [J].
JAFFRAY, DA ;
BATTISTA, JJ ;
FENSTER, A ;
MUNRO, P .
MEDICAL PHYSICS, 1993, 20 (05) :1417-1427
[18]   THE DESIGN AND PERFORMANCE-CHARACTERISTICS OF A MULTILEAF COLLIMATOR [J].
JORDAN, TJ ;
WILLIAMS, PC .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (02) :231-251
[19]   HEAD SCATTER DATA FOR SEVERAL LINEAR ACCELERATORS (4-18MV) [J].
KASE, KR ;
SVENSSON, GK .
MEDICAL PHYSICS, 1986, 13 (04) :530-532
[20]   DYNAMIC WEDGE FIELD TECHNIQUES THROUGH COMPUTER-CONTROLLED COLLIMATOR MOTION AND DOSE DELIVERY [J].
LEAVITT, DD ;
MARTIN, M ;
MOELLER, JH ;
LEE, WL .
MEDICAL PHYSICS, 1990, 17 (01) :87-91