Potentiometric measurement of ascorbate by using a solvent polymeric membrane electrode

被引:18
作者
Guo, Huimin [1 ,2 ]
Yin, Tanji [1 ]
Su, Qingmei [1 ]
Qin, Wei [1 ]
机构
[1] Chinese Acad Sci, Yantai Inst Coastal Zone Res Sustainable Dev, Environm Chem Lab, Yantai 264003, Peoples R China
[2] Dalian Univ Technol, Sch Chem Engn, Dept Chem, Dalian 116024, Peoples R China
关键词
potentiometry; ion selective electrodes; ion fluxes; polymeric membranes; ascorbate; irreversible chemistries;
D O I
10.1016/j.talanta.2007.12.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel potentiometric method for the determination of ascorbate is described in this communication. It is based on ascorbate oxidation with permanganate which is continuously released from the inner reference solution of a ligand-free tridodecylmethyl ammonium chloride (TDMAC)-based polymeric membrane ion selective electrode (ISE). The ISE potential determined by the activity of permanganate ions released at the sample-membrane phase boundary is increased with the consumption of permanganate. The proposed membrane electrode is useful for continuous and reversible detection of ascorbate at concentrations in 0.1 M NaCl ranging from 1.0 x 10(-6) to 1.0 x 10(-3) M with a detection limit of 2.2 x 10(-7) M. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 31 条
[1]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[2]   The new wave of ion-selective electrodes. [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :420A-426A
[3]   Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion [J].
Bakker, E .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) :L83-L85
[4]   Origin of anion response of solvent polymeric membrane based silver ion-selective electrodes [J].
Bakker, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) :20-25
[5]   NEW TITRIMETRIC METHOD FOR DETERMINATION OF VITAMIN-C [J].
BARAKAT, MZ ;
SHEHAB, SK ;
DARWISH, N ;
ELZOHEIR.A .
ANALYTICAL BIOCHEMISTRY, 1973, 53 (01) :245-251
[6]   CHEMICAL SENSORS BASED ON CONTROLLED-RELEASE POLYMER SYSTEMS [J].
BARNARD, SM ;
WALT, DR .
SCIENCE, 1991, 251 (4996) :927-929
[7]   Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels:: New requirements for selectivities and measuring protocols, and comparison with ICPMS [J].
Ceresa, A ;
Bakker, E ;
Hattendorf, B ;
Günther, D ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :343-351
[8]   Direct potentiometric information on total ionic concentrations [J].
Ceresa, A ;
Pretsch, E ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2050-2054
[9]   Optical peroxide biosensor using the electrically controlled-release technique [J].
Choi, JW ;
Lim, IH ;
Kim, HH ;
Min, JH ;
Lee, WH .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :141-146
[10]  
GUNSINGHAM H, 1990, ANAL CHEM, V62, P755