High sensitivity piezoresistive cantilever design and optimization for analyte-receptor binding

被引:81
作者
Yang, M [1 ]
Zhang, X [1 ]
Vafai, K [1 ]
Ozkan, CS [1 ]
机构
[1] Univ Calif Riverside, Dept Mech Engn, Riverside, CA 92521 USA
关键词
D O I
10.1088/0960-1317/13/6/309
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The mechanical design and optimization of piezoresistive cantilevers for biosensing applications is studied using finite element analysis. The change of relative resistivity of piezoresistive microcantilevers is analyzed in the presence of the chemical reaction at the receptor surface under the condition of oscillating flow. Chemo-mechanical binding forces have been analyzed in order to understand issues of saturation over the cantilever surface. Furthermore, the optimum design using finite element modeling is achieved by modifying the factors pertaining to the geometry of the microcantilevers under the condition of bio-binding. The introduction of stress concentration regions (SCRs) during cantilever fabrication has been discussed, which greatly enhances the detection sensitivity through increased surface stress. Finally, the optimum SCR modified 'C' piezocantilever system for biosensing is designed and the optimal parameters are set for high sensitivity.
引用
收藏
页码:864 / 872
页数:9
相关论文
共 14 条
  • [1] Piezoresistive cantilevers as optical sensors for scanning near-field microscopy
    Bauer, P
    Hecht, B
    Rossel, C
    [J]. ULTRAMICROSCOPY, 1995, 61 (1-4) : 127 - 130
  • [2] Brugger J., 1992, Journal of Micromechanics and Microengineering, V2, P218, DOI 10.1088/0960-1317/2/3/026
  • [3] The forward rate of binding of surface-tethered reactants: Effect of relative motion between two surfaces
    Chang, KC
    Hammer, DA
    [J]. BIOPHYSICAL JOURNAL, 1999, 76 (03) : 1280 - 1292
  • [4] Terahertz field characterization using Fabry-Perot-like cantilevers
    Dragoman, D
    Dragoman, M
    [J]. APPLIED PHYSICS LETTERS, 2001, 79 (05) : 581 - 583
  • [5] SNOM/AFM microprobe integrated with piezoresistive cantilever beam for multifunctional surface analysis
    Grabiec, P
    Gotszalk, T
    Radojewski, J
    Edinger, K
    Abedinov, N
    Rangelow, IW
    [J]. MICROELECTRONIC ENGINEERING, 2002, 61-2 : 981 - 986
  • [6] Hansen A.G., 2001, PROBE MICROSCO, V2, P139
  • [7] High-sensitivity piezoresistive cantilevers under 1000 Å thick
    Harley, JA
    Kenny, TW
    [J]. APPLIED PHYSICS LETTERS, 1999, 75 (02) : 289 - 291
  • [8] A microcantilever-based alcohol vapor sensor-application and response model
    Jensenius, H
    Thaysen, J
    Rasmussen, AA
    Veje, LH
    Hansen, O
    Boisen, A
    [J]. APPLIED PHYSICS LETTERS, 2000, 76 (18) : 2615 - 2617
  • [9] KASSEGNE S, 2002, P SPIE C SMART STRUC
  • [10] Gold Nano-Structures for Transduction of Biomolecular Interactions into Micrometer Scale Movements
    Lavrik, Nickolay V.
    Tipple, Christopher A.
    Sepaniak, Michael J.
    Datskos, Panos G.
    [J]. BIOMEDICAL MICRODEVICES, 2001, 3 (01) : 35 - 44