Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based computerized navigation

被引:55
作者
Gao Hong [1 ]
Luo Cong-Feng [1 ]
Hu Cheng-Fang [1 ]
Zhang Chang-Qing [1 ]
Zeng Bing-Fang [1 ]
机构
[1] Jiao Tong Univ, Dept Orthopaed Surg, Shanghai Peoples Hosp 6, Shanghai 200233, Peoples R China
关键词
Acetabular fracture; Minimally invasive surgery; Screw fixation; Surgical navigation; Virtual fluoroscopy; INTRAOPERATIVE FLUOROSCOPY; IMAGE GUIDANCE; OPEN REDUCTION; CT; RADIATION; SURGERY; PLACEMENT; EXPOSURE; EVALUATE; ENOUGH;
D O I
10.1007/s00402-010-1095-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The treatment of displaced acetabular fractures with formal open reduction and internal fixation has gained general acceptance. However, extensile exposure can lead to complications. Two-dimensional fluoroscopy-based computerized navigation for placement of percutaneous screw across non-displaced acetabular fractures has attracted interest by making use of stored patient-specific imaging data to provide real-time guidance in multiple image planes during implant placement. The purpose of the present study was to document early treatment results and complications associated with this new technique and evaluate its clinical application to displaced acetabular fractures amenable to closed or limited open reduction. Eighteen adult patients with 12 non-displaced and 8 displaced acetabular fractures were treated with percutaneous screw fixation under the guidance of a fluoroscopy-based navigation system. There were 14 men and four women with a mean age of 42.1 years (range 19-54 years). According to the AO and Orthopaedic Trauma Association Classification, there were nine 62-A3, five 62-B1, three 62-B2, and three 62-B3. The mean follow-up was 21 months (range 12-28 months). The mean time from injury to surgery was 4 days (range 2-7 days). A total of 30 acetabular screws were inserted, including 21 anterior column screws and 9 posterior column screws. The average operation time was 24.6 min (range 16-47 min) from the image acquisition to wound closure. The average fluoroscopic time was 28.4 s (range 11-58 s). Compared to the final position of the screw, the average deviated distance of wire tip was 2.5 mm (range 1.1-3.6 mm) and the average trajectory difference was 2.45A degrees (range 1.5A degrees-4.6A degrees). Maximal gap displacement averaged 10 mm (range 2-22 mm) preoperatively and 3 mm (range 0-5 mm) postoperatively; while maximal step displacement averaged 4 mm (range 1-10 mm) preoperatively and 2 mm (range 0-4 mm) postoperatively. One patient sustained a transient femoral nerve palsy and resolved 2 months after the operation. No superficial or deep infection occurred. Using the rating system of D'Aubigne and Postel, 13 patients had excellent results, 4 patients had good results, and 1 patient had a fair result. Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based navigation could be applied not only to non-displaced fractures but also to displaced fractures amenable to closed or limited open reduction.
引用
收藏
页码:1177 / 1183
页数:7
相关论文
共 40 条
[1]
Scattered radiation during fixation of hip fractures - Is distance alone enough protection? [J].
Alonso, JA ;
Shaw, DL ;
Maxwell, A ;
McGill, GP ;
Hart, GC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :815-818
[2]
The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures [J].
Attias, N ;
Lindsey, RW ;
Starr, AJ ;
Borer, D ;
Bridges, K ;
Hipp, JA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (11) :1520-1523
[3]
Borrelli J, 2002, J ORTHOP TRAUMA, V16, P449, DOI 10.1097/00005131-200208000-00001
[4]
Accuracy of detecting screw penetration of the acetabulum with intraoperative fluoroscopy and computed tomography [J].
Carmack, DB ;
Moed, BR ;
McCarroll, K ;
Freccero, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (09) :1370-1375
[5]
Chmelova Jana, 2005, Biomedical Papers (Olomouc), V149, P177
[6]
Crowl Adam C, 2002, Comput Aided Surg, V7, P169, DOI 10.1002/igs.10040
[7]
DAUBIGNE M, 1954, J BONE JOINT SURG AM, V36, P451
[8]
PERCUTANEOUS SCREW FIXATION OF ACETABULAR FRACTURES WITH CT GUIDANCE - PRELIMINARY-RESULTS OF A NEW TECHNIQUE [J].
GAY, SB ;
SISTROM, C ;
WANG, GJ ;
KAHLER, DA ;
BOMAN, T ;
MCHUGH, N ;
GOITZ, HT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (04) :819-822
[9]
Navigated pedicle screw placement:: Experimental comparison between CT- and 3D fluoroscopy-based techniques [J].
Geerling, Jens ;
Goesling, Thomas ;
Goesling, Anna ;
Ortega, Gil ;
Kendoff, Daniel ;
Citak, Musa ;
Krettek, Christian ;
Huefner, Tobias .
COMPUTER AIDED SURGERY, 2008, 13 (03) :157-166
[10]
Percutaneous fixation of the pelvic ring - An update [J].
Giannoudis, P. V. ;
Tzioupis, C. C. ;
Pape, H. -C. ;
Roberts, C. S. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (02) :145-154