Critical points in the fabrication of microfluidic devices on glass substrates

被引:44
作者
Castano-Alvarez, Mario [1 ]
Pozo Ayuso, Diego F. [2 ]
Garcia Granda, Miguel [2 ]
Teresa Fernandez-Abedul, M. [1 ]
Rodriguez Garcia, Jose [2 ]
Costa-Garcia, Agustin [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
[2] Univ Oviedo, Dept Fis, E-33007 Oviedo, Asturias, Spain
关键词
glass microfluidic; electrophoresis microchip; photolithography; wet etching; thermal bonding; electrochemical detection;
D O I
10.1016/j.snb.2007.09.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Miniaturized total analysis systems are becoming a powerful tool for analytical and bioanalytical applications. In this work, microfluidic channels have been fabricated on glass substrates using photolithography and wet etching. Although these techniques are well-known and established, the influence of different parameters on the fabrication process of microchannels is of great importance. Thus, practical aspects and critical points of the procedure were considered and evaluated. Resulting glass chips with microfluidic channels were sealed with a cover plate to enclose the channels. Different low and high temperature bonding procedures have been evaluated. Microfluidic chips have been used in combination with a metal-wire end-channel amperometric detector for capillary electrophoresis (CE). The microfluidic channels and the amperometric detector have been tested using p-aminophenol as model analyte demonstrating that these devices are useful for analytical applications. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:436 / 448
页数:13
相关论文
共 44 条
[1]   Discussion of tooling solutions for the direct bonding of silicon wafers [J].
Aitken, N ;
Rogers, T .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2006, 12 (05) :413-417
[2]   Polyelectrolyte-modified short microchannel for cation separation [J].
Bai, XX ;
Roussel, C ;
Jensen, H ;
Girault, HH .
ELECTROPHORESIS, 2004, 25 (06) :931-935
[3]   Fabrication of poly(dimethylsiloxane) microfluidic system based on masters directly printed with an office laser printer [J].
Bao, N ;
Zhang, Q ;
Xu, JJ ;
Chen, HY .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1089 (1-2) :270-275
[4]   Plastic microfluidic devices modified with polyelectrolyte multilayers [J].
Barker, SLR ;
Tarlov, MJ ;
Canavan, H ;
Hickman, JJ ;
Locascio, LE .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4899-4903
[5]   The introduction of powder blasting for sensor and microsystem applications [J].
Belloy, E ;
Thurre, S ;
Walckiers, E ;
Sayah, A ;
Gijs, MAM .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 84 (03) :330-337
[6]  
CARCANO G, 1993, HYBRID CIRCUITS, V32, P12
[7]   Amperometric detector designs for capillary electrophoresis microchips [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (02) :291-299
[8]   Amperometric PMMA-microchip with integrated gold working electrode for enzyme assays [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) :303-310
[9]   Poly(methylmethacrylate) and Topas capillary electrophoresis microchip performance with electrochemical detection [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
ELECTROPHORESIS, 2005, 26 (16) :3160-3168
[10]   Room temperature bonding of micromachined glass devices for capillary electrophoresis [J].
Chiem, N ;
Lockyear-Shultz, L ;
Andersson, P ;
Skinner, C ;
Harrison, DJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03) :147-152