A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography

被引:82
作者
Aristophanous, Michalis [1 ]
Penney, Bill C.
Martel, Mary K.
Pelizzari, Charles A.
机构
[1] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
positron emission tomography; mixture model; tumor volume segmentation;
D O I
10.1118/1.2791035
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The increased interest in F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) in radiation treatment planning in the past five years necessitated the independent and accurate segmentation of gross tumor volume (GTV) from FDG-PET scans. In some studies the radiation oncologist contours the GTV based on a computed tomography scan, while incorporating pertinent data from the PET images. Alternatively, a simple threshold, typically 40% of the maximum intensity, has been employed to differentiate tumor from normal tissue, while other researchers have developed algorithms to aid the PET based GTV definition. None of these methods, however, results in reliable PET tumor segmentation that can be used for more sophisticated treatment plans. For this reason, we developed a Gaussian mixture model (GMM) based segmentation technique on selected PET tumor regions from non-small cell lung cancer patients. The purpose of this study was to investigate the feasibility of using a GMM-based tumor volume definition in a robust, reliable and reproducible way. A GMM relies on the idea that any distribution, in our case a distribution of image intensities, can be expressed as a mixture of Gaussian densities representing different classes. According to our implementation, each class belongs to one of three regions in the image; the background (B), the uncertain (U) and the target (T), and from these regions we can obtain the tumor volume. User interaction in the implementation is required, but is limited to the initialization of the model parameters and the selection of an "analysis region" to which the modeling is restricted. The segmentation was developed on three and tested on another four clinical cases to ensure robustness against differences observed in the clinic. It also compared favorably with thresholding at 40% of the maximum intensity and a threshold determination function based on tumor to background image intensities proposed in a recent paper. The parts of the method that are user dependent were evaluated and resulted in initial estimates of the method's precision, which is in the order of +/- 10% of the average tumor volume estimate. With this work we have established the applicability of the GMM-based segmentation on clinical studies and we have made an initial assessment of the method's precision with respect to tumor volume segmentation. (C) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:4223 / 4235
页数:13
相关论文
共 29 条
[1]   Investigation of a 3D gradient based method for volume segmentation in positron emission tomography for radiation treatment planning [J].
Aristophanous, M ;
Martel, M ;
Pelizzari, C ;
O'Brien-Penney, B .
MEDICAL PHYSICS, 2005, 32 (06) :1895-1895
[2]  
Biehl KJ, 2006, J NUCL MED, V47, P1808
[3]   Defining a radiotherapy target with positron emission tomography [J].
Black, QC ;
Grills, IS ;
Kestin, LL ;
Wong, CYO ;
Wong, JW ;
Martinez, AA ;
Yan, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1272-1282
[4]   Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer [J].
Bradley, J ;
Thorstad, WL ;
Mutic, S ;
Miller, TR ;
Dehdashti, F ;
Siegel, BA ;
Bosch, W ;
Bertrand, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01) :78-86
[5]   Radiotherapy planning: PET/CT scanner performances in the definition of gross tumour volume and clinical target volume [J].
Brianzoni, E ;
Rossi, G ;
Ancidei, S ;
Berbellini, A ;
Capoccetti, F ;
Cidda, C ;
D'Avenia, P ;
Fattori, S ;
Montini, GC ;
Valentini, G ;
Proietti, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (12) :1392-1399
[6]   Can pet provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CY and the promise of PET [J].
Caldwell, CB ;
Mah, K ;
Skinner, M ;
Danjoux, CE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05) :1381-1393
[7]   PARTIAL VOLUME TISSUE CLASSIFICATION OF MULTICHANNEL MAGNETIC-RESONANCE IMAGES - A MIXEL MODEL [J].
CHOI, HS ;
HAYNOR, DR ;
KIM, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :395-407
[8]   Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios:: influence of reconstruction algorithms [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Doumont, T ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :247-250
[9]   Assessment of 18F PET signals for automatic target volume definition in radiotherapy treatment planning [J].
Davis, J. Bernard ;
Reiner, Beatrice ;
Huser, Marius ;
Burger, Cyrill ;
Szekely, Gabor ;
Ciernik, I. Frank .
RADIOTHERAPY AND ONCOLOGY, 2006, 80 (01) :43-50
[10]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38