Current steering and current focusing in cochlear implants: Comparison of monopolar, tripolar, and virtual channel electrode configurations

被引:129
作者
Berenstein, Carlo K. [1 ]
Mens, Lucas H. M. [1 ]
Mulder, Jef J. S. [1 ]
Vanpoucke, Filiep J. [2 ]
机构
[1] Radboud Univ Nijmegen, Nijmegen Med Ctr, KNO Audiol, NL-6500 HB Nijmegen, Netherlands
[2] Adv Bion European Res Ctr, Niel, Belgium
关键词
D O I
10.1097/AUD.0b013e3181645336
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: To compare the effects of Monopole (Mono), Tripole (Tri), and "Virtual channel" (Vchan) electrode configurations on spectral resolution and speech perception in a crossover design. Design: Nine experienced adults who received an Advanced Bionics CII/90K cochlear implant participated in a crossover design using three experimental strategies for 2 wk each. Three strategies were compared: (1) Mono; (2) Tri with current partly returning to adjacent electrodes and partly (25 or 75%) to the extracochlear reference; and (3) a monopolar "Vchan" strategy creating seven intermediate channels between two contacts. Each strategy was a variant of the standard "HiRes" processing strategy using 14 channels and 1105 pulses/see/ channel, and a pulse duration of 32 mu sec/phase. Spectral resolution was measured using broadband noise with a sinusoidally rippled spectral envelope with peaks evenly spaced on a logarithmic frequency scale. Speech perception was measured for monosyllables in quiet and in steady-state and fluctuating noises. Subjective comments on music experience and preferences in everyday use were assessed through questionnaires. Results: Thresholds and most comfortable levels with Mono and Vchan were both significantly lower than levels with Tri. Spectral resolution was significantly higher with Tri than with Mono; spectral resolution with Vchan did not differ significantly from the other configurations. Moderate but significant correlations between word recognition and spectral resolution were found in speech in quiet and fluctuating noise. For speech in quiet, word recognition was best with Mono and worst with Vchan; Tri did not significantly differ from the other configurations. Pooled across the noise conditions, word recognition was best with Tri and worst with Vchan (Mono did not significantly differ from the other configurations). These differences were small and insufficient to result in a clear increase in performance across subjects if the result from the best configuration per subject was compared with the result from Mono. Across all subjects, music appreciation and satisfaction in everyday use did not clearly differ between configurations. Conclusions: (1) Although spectral resolution was improved with the tripolar configuration, differences in speech performance were too small in this limited group of subjects to justify clinical introduction. (2) Over-all spectral resolution remained extremely poor compared with normal hearing; it remains to be seen whether further manipulations of the electrical field will be more effective.
引用
收藏
页码:250 / 260
页数:11
相关论文
共 49 条
[1]   Auditory cortical images of cochlear-implant stimuli: Dependence on electrode configuration [J].
Bierer, JA ;
Middlebrooks, JC .
JOURNAL OF NEUROPHYSIOLOGY, 2002, 87 (01) :478-492
[2]  
Bosman A. J., 1992, Woordenlijst voor spraakaudiometrie (Compact Disc)
[3]  
BUECHNER A, 2006, 9 INT C COCHL IMPL R
[4]   A silastic positioner for a modiolus-hugging position of intracochlear electrodes: Electrophysiologic effects [J].
Cords, SM ;
Reuter, G ;
Issing, PR ;
Sommer, A ;
Kuzma, J ;
Lenarz, T .
AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (02) :212-217
[5]   Place-pitch discrimination of single-versus dual-electrode stimuli by cochlear implant users [J].
Donaldson, GS ;
Kreft, HA ;
Litvak, L .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 118 (02) :623-626
[6]   The right information may matter more than frequency-place alignment: Simulations of frequency-aligned and upward shifting cochlear implant processors for a shallow electrode array insertion [J].
Faulkner, A ;
Rosen, S ;
Norman, C .
EAR AND HEARING, 2006, 27 (02) :139-152
[7]  
FIRSZT J, 2004, ADV BIONICS WEB SITE
[8]   Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor [J].
Fishman, KE ;
Shannon, RV ;
Slattery, WH .
JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 1997, 40 (05) :1201-1215
[9]   Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants [J].
Friesen, LM ;
Shannon, RV ;
Baskent, D ;
Wang, X .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 110 (02) :1150-1163
[10]   The importance of human cochlear anatomy for the results of modiolus-hugging multichannel cochlear implants [J].
Frijns, JHM ;
Briaire, JJ ;
Grote, JJ .
OTOLOGY & NEUROTOLOGY, 2001, 22 (03) :340-349