Electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of trace amount of lanthanides and yttrium in soil with polytetrafluroethylene emulsion as a chemical modifier

被引:38
作者
He, M [1 ]
Hu, B [1 ]
Jiang, ZC [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
ETV-ICP-MS; lanthanides; yttrium; soil; matrix effect; polytetrafluorethylene;
D O I
10.1016/j.aca.2004.08.074
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method of electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) for the determination of trace lanthanides and yttrium in soil samples with a polytetrafluorethylene (PTFE) emulsion as chemical modifier to promote the vaporization of the analytes from the graphite furnace was developed in this paper. The analytical characteristics, spectral interference and matrix effect of the analytical method were evaluated and critically compared with those of pneumatic nebulization inductively coupled plasma mass spectrometry (PN-ICP-MS). Under the optimized operation conditions, the relative detection limits of lanthanides (La-Lu) and yttrium for ETV-ICP-MS and PN-ICP-MS were 0.4-20 ng l(-1) and 1.0-21 ng l(-1), respectively, the absolute detection limits for ETV-ICP-MS were 4-200 fg, which were improved by 1-2 orders of magnitude compared with PN-ICP-MS. While the analytical precision of ETV-ICP-MS is worse than that of PN-ICP-MS, with the R.S.D.s (%) of 4.1-10% for the former and 2.9-7.8% for the latter. Regarding to the matrix effect, both conventional method and stepwise dilution method were employed to observe the effect of matrix and the very similar results were obtained. It was found that the highest tolerance concentration of the matrix is 1000 mg l(-1) and 800 mg l(-1) for ETV-ICP-MS and PN-ICP-MS, respectively. To assess the accuracy, the proposed method was applied to the determination of trace lanthanides and yttrium in three different soil standard reference materials and one soil sample, and the determined values are in good agreement with the certified values or reference values. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 38 条
[1]   Correction for non-spectroscopic matrix effects in inductively coupled plasma-mass spectrometry by common analyte internal standardization [J].
Al-Ammar, AS ;
Gupta, RK ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (13) :1849-1860
[2]   Spectral interferences in the determination of traces of scandium, yttrium and rare earth elements in 'pure' rare earth matrices by inductively coupled plasma atomic emission spectrometry: Part VI - Ytterbium [J].
Aleksieva, L ;
Daskalova, N ;
Velichkov, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (08) :1339-1350
[3]   Determination of sub-parts-per-trillion levels of rare earth elements in natural waters by inductively coupled plasma time-of-flight mass spectrometry after flow injection on-line sorption preconcentration in a knotted reactor [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :995-1001
[4]   Determination of rare earth elements in urine by electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Bettinelli, M ;
Spezia, S ;
Terni, C ;
Ronchi, A ;
Balducci, C ;
Minoia, C .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) :579-584
[5]   Investigation and quantification of spectroscopic interferences from polyatomic species in inductively coupled plasma mass spectrometry using electrothermal vaporization or pneumatic nebulization for sample introduction [J].
Björn, E ;
Frech, W ;
Hoffmann, E ;
Lüdke, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (13) :1765-1776
[6]   Determination of endogenous concentrations of the lanthanides in body fluids and tissues using electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Buseth, E ;
Wibetoe, G ;
Martinsen, I .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :1039-1049
[7]   Elimination of the spectral interference from polyatomic ions with rare earth elements in inductively coupled plasma mass spectrometry by combining algebraic correction with chromatographic separation [J].
Cao, XD ;
Yin, M ;
Wang, XR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (04) :431-441
[8]  
Chen SZ, 1999, J ANAL ATOM SPECTROM, V14, P1723
[9]   Preconcentration and elimination of matrix effects in XRF determinations of rare earth elements by preparing a thin film through chemofiltration [J].
De Vito, IE ;
Olsina, RA ;
Masi, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) :275-278
[10]   Determination of rare earth elements in soils and sediments by inductively coupled plasma atomic emission spectrometry after cation-exchange separation [J].
Djingova, R ;
Ivanova, J .
TALANTA, 2002, 57 (05) :821-829